Ethernet™ Pocket Hub™

5. MAINTENANCE

WARNING: DO NOT, UNDER ANY CIRCUMSTANCES,
open and attempt to repair the 0402 Pocket Hub or power
supply adapter unit.  Failure to observe this warning could
result in personal injury or death from electrical shock.

NOTE: Failure to observe the above warning will immediately void
the warranty.

Fault Isolation

If two network devices fail to communicate through the 0402
Pocket Hub, consider the following:

Are the LEDs described in the previous section functioning
properly?

Do network devices have Link Integrity enabled?

Do network devices communicate when the 0402 Pocket
Hub is not installed between them? 

Is flat or “silver satin” wire used in site internal wiring?

Are internal wiring patch cords, punch down blocks, and
wall jacks properly pinned or configured?

Is the AUI cable unbroken and properly connected?

Are network interface cards properly configured?

Technical Support Contact

For assistance in fault isolation and in maintaining the 0402 Pocket
Hub, contact: 

Technical Support

(800) 260-1312

or your local distributor.

0402 Ethernet Pocket Hub Connectors and
Status LEDs

RJ-45 Connectors

Four (4) 10BaseT RJ-45 jack
connectors are located at one
end of the 0402 Pocket Hub.
The RJ-45  jacks support
connection to shielded or
unshielded 100 ohm twisted
pair 10BaseT cable. 

Power Supply Adapter Connectors

An external power supply
adapter connector is located
at the other end of the 0402
Pocket Hub. The power
supply adapter connector
supplies external power. 

Status LEDs

Power and Link/Transmit
status LEDs are located at
the side of the 0402 Pocket
Hub. The Power LED
indicates connection to
power. The Link/ Transmit
LEDs track the four 0402
Pocket Hub connections to
10 BaseT.

RJ-45 Connectors

Power Supply Adapter
Connector

Status LEDs

Summary of Contents for 402

Page 1: ...ysical Dimensions 4 80 X 2 77 X 0 95 122mm x 70mm x 24mm Input Power Power Supply Adapter AC Input TN PN Requirement Location 3518 120 volts 60 hertz 28 watts USA Canada Mexico 3516 230 volts 50 hertz 28 watts Europe 3514 100 volts 50 60 hertz 28 watts Japan 3517 240 volts 50 hertz 28 watts United Kingdom 3515 240 volts 50 hertz 28 watts Australia DC Output 9 volts at 500 mA maximum MTBF 43 000 ho...

Page 2: ...rstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität 10Base2 Cable Specifications The physical characteristics of the 10Base2 cable must meet or exceed IEEE 802 3 10Base2 specifications Cable Char...

Page 3: ...ded Connector Legend 1 Logic Ref 6 Power Return 11 Logic Ref 2 Collision 7 N C 12 Receive 3 Transmit 8 Logic Ref 13 Power 4 Logic Ref 9 Collision 14 Logic Ref 5 Receive 10 Transmit 15 N C 10BaseFL Cable and Connector Specifications The physical characteristics of the 10BaseFL cable must meet or exceed IEEE 802 3 10BaseFL specifications 10BaseFL Cable Characteristics Fiber Optic Cable Recommended 6...

Page 4: ...ty shall not exceed the amount paid to TN for the product directly related to the alleged damage However in no event shall TN have any liability to a customer or any third party for products manufactures according to the customer s specifications C Return Procedure The customer must follow this procedure for the return of defective items 1 Locate the serial number s of the item s to be returned 2 ...

Page 5: ...THE ABOVE WARRANTY IS EXCLUSIVE AND EXTENDS ONLY TO PRODUCTS ASSEMBLED BY TRANSITION NETWORKS INC TO THE EXTENT PERMITTED BY LAW TN DOES NOT MAKE AND DISCLAIMS ALL OTHER WARRANTIES EXCEPT TITLE EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF DESCRIPTION MERCHANTIBILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT AND ANY WARRANTY BASED UPON PRIOR WRITTEN OR ORAL REPRESENT...

Page 6: ...ed or configured Is the AUI cable unbroken and properly connected Are network interface cards properly configured Technical Support Contact For assistance in fault isolation and in maintaining the 0402 Pocket Hub contact Technical Support 800 260 1312 or your local distributor 0402 Ethernet Pocket Hub Connectors and Status LEDs RJ 45 Connectors Four 4 10BaseT RJ 45 jack connectors are located at o...

Page 7: ... The site for the 0402 Ethernet Repeater Hub must provide AC power outlet for each Hub Adequate ventilation Standard environmental conditions Isolation from electrical noise including radio transmitters and broadband amplifiers motors high power electrical lines or fluorescent light fixtures Additionally The twisted pair cables should not run in the same conduit with power line cables Phone lines ...

Page 8: ...necting Pocket Hubs the transmission path between any two Data Terminating Equipment DTE terminals can consist of no more than five segments To assign segment numbers to cable connections 1 Determine the two terminals in the network which are separated by the greatest number of segments 2 Assign a segment path between the terminals by labeling the cable connected to one of the terminals segment 1 ...

Page 9: ...at RJ 45 Plug Hub Hub RJ 45 Male RJ 45 Male 1 3 2 6 3 1 6 2 Connecting two Pocket Hubs Use a crossover cable to connect Pocket Hubs Use a straight through cable to connect Pocket Hub to terminal devices Connecting Pocket Hub to Terminal Devices Use a straight through cable to connect Pocket Hub to terminal devices Ethernet Pocket Hub n e t w o r k s T R A N S I T I O N Mpls MN 55344 Ethernet Pocke...

Page 10: ...eT Cable to Pocket Hub RJ 45 connectors 1 Locate or build 10BaseT cables with the following characteristics 803 2 compliant See page 14 correct straight through or crossover cable configuration for site installation See page 7 male RJ 45 plug connectors installed at both ends of cable 2 Connect male RJ 45 plug connector at one end of 10BaseT cable to Pocket Hub RJ 45 jack connector 3 Connect male ...

Reviews: