Maintenance

 

The electrodes must be regularly cleaned to maintain good ionizing per-

formance.  Frequency of cleaning is dependent on the cleanliness of the 

environment and requirements of the ESD program.  At least once a 

month is a suggested frequency.  Note:  Do not clean ionizer when pow-

ered on.

 

1. Power off the ion bar and let sit for 10 minutes.

 

2. Clean the electrode tip, discharge pad and metal discharge body with 

alcohol and a clean cloth.

 

3. Do not power on the ion bar until the components are completely dry.

 

 

Calibration 

 

The SCION IN1200 ion output is inherently balanced by design, so there 

are no calibration adjustments. Periodic verification is recommended, per 

ANSI/ESD SP3.3

-

2006 Periodic Verification of Air Ionizers. Verification fre-

quency may be set by the individual user, but is recommended to be not 

less than one time per year.

 

Equipment needed is a Charge Plate Monitor such as Transforming Tech-

nologies EFM51.CPS.SET or CPM74.  Test the ionizer's ion output and bal-

ance  according to the Charge Plate's instructions.

 

Ion Output Check: Discharge times should be 2 seconds (1000v

-

100v) at 

18".

 

Ion Balance Check: Offset voltage should be measured and be 30 

volts.

 

 

 

 
 
 
 
 
 
 
 
 

 

 
 
 

EFM51.CPS.SET 

-

CPM74

-

 Charge Plate

 

Summary of Contents for SCION IN1200 Series

Page 1: ...Model IN1200 Series Instruction Manual T R A N S F O R M I N G T E C H N O L O G I E S L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L...

Page 2: ...N1200 ionizing bar is designed to reduce static charge in mini environments laminar flow hoods and wide are applications Available in four different lengths Features 1 Aerodynamic bar design 2 AC Squa...

Page 3: ...sive environments 6 Electrodes must not come in contact with metal conductors 7 Please contact Transforming Technologies Customer Service for repair information Installation 1 Choose optimal location...

Page 4: ...d measured in Hz at which the ion bar makes a full cycle from the positive current to the negative and back to positive The bar can be adjusted from 1Hz slowest to 50Hz fastest The Working Frequency u...

Page 5: ...oltage cycle N Only negative voltage cycle Bar Adjusts the ion bar working frequency C Rest The bar can be set from 1hz slowest to 50hz fastest by pressing Bar and then a number Bar 1 Set ion bar work...

Page 6: ...ly dry Calibration The SCION IN1200 ion output is inherently balanced by design so there are no calibration adjustments Periodic verification is recommended per ANSI ESD SP3 3 2006 Periodic Verificati...

Page 7: ...r acci dent In no event shall Transforming Technologies be liable for collateral or consequential damages To receive service under warranty please contact Transforming Technologies Technical Support A...

Page 8: ...3719 King Rd Toledo OH 43617 P 419 841 9552 F 419 841 3241 info transforming technologies com...

Reviews:

Related manuals for SCION IN1200 Series