5
2. Periodic Maintenance
The only maintenance required for BFN series ionizers is
the periodic cleaning of the emitter points, inlet and out-
let finger guards and the fan assembly. Emitter point
cleaning affects the static decay ability of the ionizer and
is important for maintaining its optimal performance.
Emitter point cleaning:
All BFN series ionizing blow-
ers include an integrated emitter point cleaning brush on
the inlet fan guards. Turn the emitter point cleaners
clockwise, then counter clockwise several times, until
points are clean. When finished, return the point cleaning
brush to its resting position.
CAUTION: Brushes do not
spin 360 degrees. Stopping point is on the bottom
right of fan guard. Do Not Force.
Internal fan cleaning:
All BFN series ionizing blowers
offer convenient cleaning of the internal fan assembly.
Use the following procedure to maintain cleanliness.
Note:
Always disconnect the ionizer from the power
source prior to internal cleaning.
Air Outlet Disassembly
A. Press the button on the bottom of the plastic front
cover upwards and make the lower portion of the fan
Operating Guide Cont.