Power Requirements 

120 V AC, 60 Hz., 110W 
220 V AC, 50Hz. 

 

Dimensions

 

 

 

38.78” W x 6.75” H x 3.35” D 

 

(58.5 W x 17.2 H x 8.5 D cm)

 

 

Weight

 

 

 

18.7 lb (8.5 kg)

 

 

Air Volume 

 

 

150 CFM 

 300 CFM [low 

high]

 

 

Effective Coverage 

2’ x 4’ area coverage

 

 

Balance

 

 

 

0

 

+10 volts

 

 

Decay Time 

 

 

< 3 seconds @ 18”, directly un-

der center of unit, 1000V-100V, 
fan speed on high

 

 

Temperature

 

 

 

32-122° F (0-50° C) 

 

RH operating range 

 

20-60%, non-condensing 

 

 

Ozone Production

 

 

< 0.003 ppm, 12” in front of 

unit, EPA EQOA577019

 

 

Indicators 

 

 

ON/OFF status light  indicator, 
detects presence of HV on 
emitter points

 

 

Light Output 

 

 

LED Lamp 

 

Light Color Temperature 

2500 K 

 

Replacement Lamp 

T4/5W fluorescent lamp 
 

Audible Noise

 

 

52dB(A), (Distance 1 meter) 

 

Enclosure

   

 

Steel 

 

Finish 

Powder coat, off white

 

 

Approvals 

 

CE

 

Product Specifications 

Packing list: 

 

BFN 803 ionizing blower 

 

Power cord 

 

Instruction manual 

 

Certificate of Conformance 

 

Mounting Brackets 

Summary of Contents for BFN 803

Page 1: ...BFN 803 Ionizing Blower Instruction Manual T R A N S F O R M I N G T E C H N O L O G I E S L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L...

Page 2: ...1 BFN 803 BFN Series 1 Description 2 Features 2 Specification 3 Operating Guide 4 Dis Assembly 6 Periodic Verification 9 2 About Service warranty 10 Transforming Technologies 10 Contents...

Page 3: ...AC ionizing blowers are designed for safe operation under normal use Safety switches under the front and rear removable finger guards shut off the unit protecting the operator during maintenance Do no...

Page 4: ...quipped with 2 LED task lights integrated emitter cleaners and safe easy maintenance access BFN series AC ionizers from Transforming Technologies create a dense and well balanced ionization current Th...

Page 5: ...ure 32 122 F 0 50 C RH operating range 20 60 non condensing Ozone Production 0 003 ppm 12 in front of unit EPA EQOA577019 Indicators ON OFF status light indicator detects presence of HV on emitter poi...

Page 6: ...nit Operating Guide 1 Power Connection Properly locate and install the ionizer into the proper po sition and connect the power cord Mounting brackets lo cated on the back right and left are used hang...

Page 7: ...point cleaners clockwise then counter clockwise several times until points are clean When finished return the point cleaning brush to its resting position CAUTION Brushes do not spin 360 degrees Stop...

Page 8: ...ely remove cover and set aside C B A Air Inlet Disassembly A Press the recessed release point on the bottom of the plastic rear cover using a flat blade screw driver B Gently push the cover upwards C...

Page 9: ...required for optimal per formance from BFN ionizers depends on the environment in which the BFN series ionizer operates When finished cleaning replace both front and rear fan guards Air Outlet Assembl...

Page 10: ...n ing of the product Periodic Verification BFN ionizer have no user serviceable parts and the technology requires no calibration because of the in herently stable ionization output from the AC emis si...

Page 11: ...or accident In no event shall Transforming Technologies be liable for collateral or conse quential damages To receive service under warranty please contact Transforming Technologies Technical Sup port...

Page 12: ...3719 King Rd Toledo OH 43617 P 419 841 9552 F 419 841 3241 info transforming technologies com...