Choosing a Power Supply

Consider these factors when choosing a power supply:

1.  Input voltage: 19V to 30V DC or 19V to 27V AC RMS @47 to 63 Hz 

In-rush current: 8A maximum, ≤25 ms. 

(See Power Requirements on Page 1 for additional Encompass 6 

requirements)

2.  Operating temperature of power supply and power cable
3.  Power cable gauge and length: 12 to 22 AWG cable, depending on 

length of cable route

Power Supply Accessory Kit

Part Number

Description

76-6000-001

110V AC or 220V AC to 24V AC transformer

CAUTION: Wire gauge depends on wire resistance 

versus overall wire length with respect to the Encompass 

6 reader’s specified voltage range and power rating.

AC Power Wiring Diagram

Refer to Encompass Reader System Guide for DC Power Wiring 

Diagram.

Power LEDs 

(Item 10 on Page 1)

POWER LED

INDICATION

-5.5

-5.5 volt power supply functioning

+7

+7 volt power supply functioning

+5.5

+5.5 volt power supply functioning

+10.5

+10.5 volt power supply functioning

+5

+5 volt power supply functioning

PWR

19V to 30V DC or 19V to 27V AC supplied

Fault/Operational LEDs 

(Item 11 on Page 1)

OPERATIONAL LEDs INDICATION
DL

RF downlink signal on

UL

RF uplink signal on

TIF

Encompass 6 transacting with tag. LED lit when 

Encompass 6 receives correctly decoded tag 

message including correct cyclic redundancy 

check for message. The LED is lit for 250 ms 

following a tag transaction.

LC

Host communicating with Encompass 6

RDR

Encompass 6 communicating with host

THREE FAULT INDICATION LEDs*

ERR3 ERR2 ERR1 FAILURE MODE

Microprocessor  resetting

Power supply failure

Transceiver failure

TDM/GPS failure

No communication with lane controller/host

Other failure

Data in buffer

No failure

*I

f multiple faults occur, the highest priority fault displays. For example, if the 

microprocessor is resetting (highest priority) and the power supply fails (second 
highest priority), the microprocessor fault indication displays until is it cleared.

Encompass 6 Quick Reference Card

Equipment Licensing

The user is required to obtain a Part 90 site license from the FCC to 

operate the unit in the United States. Access the FCC Web site at 

www.fcc.gov

 for more information.

FCC ID:  FIHMPI6000 A

Users in all countries should check with the appropriate local 

authorities for licensing requirements.

Start Up

Perform the following startup procedures:

1.  Connect antenna to Encompass 6 at RF MONO port.
2.  Connect COM1 or Ethernet cable depending on communication  

configuration.

3.  Connect other options as needed.
4.  Connect AC or DC power to Encompass 6. Power LEDs should light.
5.  Encompass 6 starts up in Mode 0 (Stop).
6.  Set commands as required for your configuration.
7.  Send Set Mode command to Encompass 6 from host.

Troubleshooting

Perform these troubleshooting procedures:

1.  Make sure all connectors are secure.
2.  Make sure Encompass 6 is powered up by checking Power LEDs.
3.  Make sure Encompass 6 is communicating with host.

If system does not respond to troubleshooting, contact TransCore 

Customer Service at transcore.com/rfidsupport.