Choosing a Power Supply
Consider these factors when choosing a power supply:
1. Input voltage: 19V to 30V DC or 19V to 27V AC RMS @47 to 63 Hz
In-rush current: 8A maximum, ≤25 ms.
(See Power Requirements on Page 1 for additional Encompass 6
requirements)
2. Operating temperature of power supply and power cable
3. Power cable gauge and length: 12 to 22 AWG cable, depending on
length of cable route
Power Supply Accessory Kit
Part Number
Description
76-6000-001
110V AC or 220V AC to 24V AC transformer
CAUTION: Wire gauge depends on wire resistance
versus overall wire length with respect to the Encompass
6 reader’s specified voltage range and power rating.
AC Power Wiring Diagram
Refer to Encompass Reader System Guide for DC Power Wiring
Diagram.
Power LEDs
(Item 10 on Page 1)
POWER LED
INDICATION
-5.5
-5.5 volt power supply functioning
+7
+7 volt power supply functioning
+5.5
+5.5 volt power supply functioning
+10.5
+10.5 volt power supply functioning
+5
+5 volt power supply functioning
PWR
19V to 30V DC or 19V to 27V AC supplied
Fault/Operational LEDs
(Item 11 on Page 1)
OPERATIONAL LEDs INDICATION
DL
RF downlink signal on
UL
RF uplink signal on
TIF
Encompass 6 transacting with tag. LED lit when
Encompass 6 receives correctly decoded tag
message including correct cyclic redundancy
check for message. The LED is lit for 250 ms
following a tag transaction.
LC
Host communicating with Encompass 6
RDR
Encompass 6 communicating with host
THREE FAULT INDICATION LEDs*
ERR3 ERR2 ERR1 FAILURE MODE
●
●
●
Microprocessor resetting
●
●
Power supply failure
●
●
Transceiver failure
●
TDM/GPS failure
●
●
No communication with lane controller/host
●
Other failure
●
Data in buffer
No failure
*I
f multiple faults occur, the highest priority fault displays. For example, if the
microprocessor is resetting (highest priority) and the power supply fails (second
highest priority), the microprocessor fault indication displays until is it cleared.
Encompass 6 Quick Reference Card
Equipment Licensing
The user is required to obtain a Part 90 site license from the FCC to
operate the unit in the United States. Access the FCC Web site at
www.fcc.gov
for more information.
FCC ID: FIHMPI6000 A
Users in all countries should check with the appropriate local
authorities for licensing requirements.
Start Up
Perform the following startup procedures:
1. Connect antenna to Encompass 6 at RF MONO port.
2. Connect COM1 or Ethernet cable depending on communication
configuration.
3. Connect other options as needed.
4. Connect AC or DC power to Encompass 6. Power LEDs should light.
5. Encompass 6 starts up in Mode 0 (Stop).
6. Set commands as required for your configuration.
7. Send Set Mode command to Encompass 6 from host.
Troubleshooting
Perform these troubleshooting procedures:
1. Make sure all connectors are secure.
2. Make sure Encompass 6 is powered up by checking Power LEDs.
3. Make sure Encompass 6 is communicating with host.
If system does not respond to troubleshooting, contact TransCore
Customer Service at transcore.com/rfidsupport.
16-0097-001 Rev A 8/17
-5.5
+10.5 +5
+5.5
+7
PWR
DL
LC RDR
TIF
UL
ERR3 ERR2 ERR1