Installing the AR2200 RF Module
3-13
1.
Terminate cable shields at the reader end.
Table 3-7 Connecting Wires Between the RF Modules and the Reader Interface
RF Module Signal
AI12XX Terminal
AI1301 RF Interface
Board Terminal
RFGND
43
NA
RFPWR
42
NA
SCTRTNI
43
NA
SCTCTLI
36
NA
RFCTLO
40 (RF module 0
only)
10 (RF module 0 only)
RFCTL1
41(RF module 1
only)
12 (RF module 1 only)
ANCHA1
45
1
ANACA2
46
2
ANCHB1
47
3
ANCHB2
48
4
ANCHC1
49
5
ANCHC2
50
6
Table 3-8 Maximum Cable Lengths for Power Wiring and Signal Wiring
Application
Cable Type
(or equivalent)
Maximum Length
Power wiring
Belden 9364
120 ft (36.6 m)
Power wiring
Belden 9365
200 ft (61.0 m)
Power wiring
Belden 9366
300 ft (91.4 m)
Power wiring
Belden 9357
500 ft (152.4 m)
Power wiring
Manhattan 33867
500 ft (152.4 m)
Signal wiring
Belden 9775
500 ft (152.4 m)
Summary of Contents for AR2200
Page 2: ......
Page 5: ...Contents ...
Page 6: ......
Page 10: ...AR2200 RF Module User Guide x ...
Page 11: ...1 Before You Begin ...
Page 12: ......
Page 16: ...AR2200 RF Module User Guide 1 6 ...
Page 17: ...2 Overview of AR2200 RF Module ...
Page 18: ......
Page 24: ...AR2200 RF Module User Guide 2 8 ...
Page 25: ...3 Installing the AR2200 RF Module ...
Page 26: ......
Page 40: ...AR2200 RF Module User Guide 3 16 ...
Page 41: ...4 Testing the RF Module ...
Page 42: ......
Page 45: ...5 Indicator Lights ...
Page 46: ......
Page 48: ...AR2200 RF Module User Guide 5 4 ...
Page 49: ...6 Adjusting RF Power ...
Page 50: ......
Page 53: ...7 Range Modulation Sensitivity Adjustment ...
Page 54: ......
Page 57: ...A AR2200 Technical Specifications ...
Page 58: ......