User Menu Descriptions

 

 

 

A1

 

Baud Rate 

Selects the baud rate for data transmission through the serial port. 

1200       2400 
4800       9600 

A2

 

Data Bits and 
Parity

 

Selects the number of data bits and parity of serial transmission. 

"8" = 8 data bits with no parity bit 

"7O" = 7 data bits with odd parity bit 

"7E" = 7 data bits with even parity bit 


7O 
7E 

A3

 

Mode of Serial 
Transmission

 

Selects when data will be sent out of the serial port to a printer or 
computer: 

"C" = Continuous mode; send data continuously 

"d" = Demand mode; send data when a PRINT command is issued 

from the printer, computer, or indicator. 


A4 

Serial Data 
Format

 

Selects either full duplex mode or multi-item print mode. See Serial 
Data Format section for more information. 

"0" = Full Duplex Mode 

"1" = Multi-item (Simplex) Mode 



 

A5 

Auto Power Off 
Period

 

Selects the auto power off time in minutes. Scale must be idle during 
this period. 

"OFF" = Indicates this feature is disabled. 

OFF, 1, 3, 5, 10, 
15, 20, 30 

NAME/CODE

DESCRIPTION

CODE/VALUE

Notes on A5 Auto Power Off Period: 

1.  Should be set to “OFF” if there is no internal battery. 

2.  The scale “chirps” three times with 30 seconds left, then “chirps” three times again with 3 

seconds left before it shuts itself off. 

 

Multi-Item Print

 

 

 

The EL-3000 comes standard with a feature called “Multi-item Print”. This allows the user to have a 
printout of each weighment transaction plus the total. To enable this feature, select “1” for A4 in the 
User Menu and plug a serial printer into the DB-9 connector on the back of the scale. You may also 
need to alter the serial parameters A1 and A2 in order to match the printer’s requirements. 

Shown at right is an example of the multi-item 
print function. Each weighment is printed when the 

M+

 key is pressed. The total accumulated weight 

is pressed when the 

MR

 key is pressed. 

+       0.4405 LB

5T       9.5980 LB 

+       4.4075 LB

+       2.4435 LB

+       1.6595 LB

+       0.6470 LB

 

 

8

   

Revision 2.95 

Summary of Contents for EL 3000

Page 1: ...1 April 16 2002 1995 2002 Transcell Technology Inc Contents subject to change without notice Transcell Technology Inc 975 Deerfield Parkway Buffalo Grove IL 60089 Tel 847 419 9180 Fax 847 419 1515 E m...

Page 2: ...warranty Table of Contents Introduction 1 Getting Started 1 Basics of Operation 2 Percentage Operation 3 Piece Counting Operation 4 Accumulator Function Operation 5 Disabling or Enabling Units 6 User...

Page 3: ...r unpacking the scale a small amount of assembly is required Locate the sub platform four 4 Hex screws and enclosed Allen wrench Place sub platform onto scale s load point with all rubber parts facing...

Page 4: ...ntage modes Low Battery Indication INDICATION MEANING Weight Indicates the weight currently on the platform When the full scale capacity has been exceeded the scale shows Units Indicates the unit of t...

Page 5: ...the MODE key to escape G oz T N lb pcs OK HI LO O E kg 2 Press the ZERO key to zero the scale 3 Place the sample on the platform all at once When the Stable flag becomes lit the display should look li...

Page 6: ...ication If the following message does not appear press the SAMPLE key once This display indication is prompting you to place 10 identical samples on the platform all at once NOTE If you entered this s...

Page 7: ...MODE key to toggle to the desired unit you wish to count 2 If the MEM indication is lit press and hold the ZERO CLEAR key to clear the accumulator memory The scale briefly displays CL to indicate tha...

Page 8: ...tch on the bottom of the scale near the back 2 While holding down the MODE key turn the scale back on Continue holding down the MODE key until the scale shows the LB unit with either the ON message or...

Page 9: ...ave or SET the selections Complete directions start below To place the unit in USER MENU mode Turn the scale off While holding down the MR key turn the scale back on When the display shows A1 the unit...

Page 10: ...utes Scale must be idle during this period OFF Indicates this feature is disabled OFF 1 3 5 10 15 20 30 NAME CODE DESCRIPTION CODE VALUE Notes on A5 Auto Power Off Period 1 Should be set to OFF if the...

Page 11: ...cline in the usage period This is due to the bat tery s reluctance to accept a charge Therefore always charge the scale for at least 10 hours before using 3 The charger may be left connected to the sc...

Page 12: ...ghtmost digit should be flashing Place the test weight on the platform 4 Use the four directional keys shown above to adjust the displayed value to the actual test weight value Increase the flashing d...

Page 13: ...erface to printers the Demand mode allows control from a host device usually a PC and can be activated by pressing the MR key on the front panel Full Duplex Continuous Mode XXXX XXX UNITS S1 ETX Polar...

Page 14: ...ogy Demand Mode Valid Weight Reading 1 Recognized host command s P for weight Data Z to zero the scale C to change displayed units S1 ETX End Transmission Status Character 1 See Continuous Mode Questi...

Page 15: ...cid battery Charger AC Adapter 15 VDC 800mA Charge Period 8 10 hours WEIGHT Net Weight 8 8 lbs 4 kg Shipping Weight 14 2 lb 6 4 kg Battery Option Add 1 2 lb 0 5 kg SERIAL PORT Full Duplex RS 232 forma...

Page 16: ...affect stability Scale should be located away from air conditioners fans fume hoods etc A breeze shield may be required D Extreme changes in room temperature can affect the internal calibration of th...

Page 17: ...exists and was not caused by accident misuse neglect alteration improper installation improper or un authorized repair or improper testing and 4 Such goods have not been modified altered or changed b...

Reviews: