Series 800
Maintenance Manual
Specifications and Requirements
Page
Rev C
Mar-03
Confidential Information: Not for Distribution.
10
Print Characteristics
The statistics for the internal fonts the 800 Series Printer supports appear below. Height and width are
expressed in terms of dots.
Height
Width
Horizontal cpi
Vertical cpi
24
12
16.9
8.4
32
16
12.7
6.4
32
20
10.2
6.4
56
28
7.3
3.6
Table 1 Font Statistics
Black Dot Position and Presentation Scheme
All graphics preprinted on the ticket must be in thermal paper compatible ink.
Black Dot Position
The back of the ticket is used for the Black Dot/Top of Form indicator. For the printer to sense when a
ticket has been indexed to the printing position, a Black Dot/Top of Form sensor is needed. It must be
printed in black, thermal paper compatible, infrared readable ink. The 10.16mm area in line with the Black
Dot/Top of Form indicator and the ticket edge (keep-out zone) must remain clear, as the Ticket Out Sensor
will read that area while the ticket is printed and presented. The remaining area on the back of the ticket
may be used for rules and disclaimer.
Figure 4 Location of Black Dot/Top of Form Indicator on Back of Ticket