4.    TROUBLES AND CAUSES 

owner's manual 

NOTE 

Protective device may start if running the unit outside the 
above condition, which will prevent the unit from operation.  

Features of heating operation 

 
Warm air will not be blown out immediately at the beginning of 
the heating operation, after 3~5minutes (depends on the indoor 
and outdoor temperature), until the indoor heat exchanger 
become hot, then blows out warm air. 
 
During operation, the fan motor in the outdoor unit may stop 
running under high temperature. 
 
During Fan operation, if other indoor Units are running on 
heating mode, the fan may stop in order to prevent sending heat 
wind. 
 

Defrost in the heating operation 

 
During heating operation, outdoor unit sometimes will frost. To 
increase efficiency, the unit will start defrosting automatcally 
(about 2~10 minutes), and then water will be drained out   from 
outdoor unit. 
 
During defrosting, both the fan motors in the outdoor unit and 
indoor unit will stop running. 
 

Operation conditions 

For proper performance, run the air conditioner under the     
following temperature conditions: 

 

 

 

 

 

 

Room 

-5°C ~ 48°C

-5°C ~ 24°C

17°C ~ 32°C

17°C ~ 32°C

   Cooling mode 

   Cooling mode 

   Heating mode 

 
   Heating mode    

 
   Mixed mode    

 
 

Mode 

Temperature 

 

Outdoor 

temperature 

Indoor 

temperature 

Room relative 

humidity 

   below 80% 

   Table.3-1 

-20°C ~ 24°C

27°C

27°C

Protection Device  

This  protection device will stop the unit automatically in case 
the air conditioner is on forced running mode. When protection 
device is activated, running indicator light is lightened and 
query light flashes.Protection device may start under the 
following circumstances: 
 
cooling operation: 
 

   The air inlet or air outlet of outdoor unit is blocked. 

 

   Strong wind is continuously blowing to the air outlet of the  

     outdoor unit. 
 
heating operation: 
 

   Too much dust and rubbish adhere to the dust filter in the  

      indoor unit 

CAUTION 

In case the following malfunctions, please switch off the 
power and contact the local dealer.Incorrect ON/OFF 
operation 
 
Fuse or leakage protector is frequently broken. 
 
Foreign matter or water falls in the unit. 

 

NOTE 

Please switch off the power when protection device starts. 
Do not restart until the problems are solved. 

Power cut 

 

  If power is cut during operation, stop all the operation  

    immediately. 
 

  Power comes again. The operation indicator on the wire  

    controller flashes. 
 

  Push the ON/OFF button again if you want to restart the  

    unit. 
 

Mishanding in operation 

 
In case of mishandling caused by lighting or mobile wireless, 
please switch off the manual power off the manual power. 
Push ON/OFF again when restarting. 
 

Heating capacity 

 

  The heating process is :absorb heat  from outdoor, while  

    expel heat to indoor by hot pump. Once the outdoor    
    temperature drop down, heating capacity is degraded  
    correspondingly. 
 

  It is command to equip with other warming facility, when  

    outdoor temperature is low. 

 

  It is better to equip with additional purchase indoor  

    auxiliary heating device in paramos area where is in  
    particularly  low outdoor temperature.(See Indoor Unit  
    Operation Manual for detail information) 

Summary of Contents for TVR 5G

Page 1: ...DC Inverter Heat Recovery TVR 5G OWNER S MANUAL Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future refere...

Page 2: ...ealer for instructions Never replace a fuse with that of wrong rated current or other wires when a fuse blows out Use of wire or copper wire may cause the unit to break down or cause a fire Do not ins...

Page 3: ...ioner for at least 12 hours before operation Do not switchoff the power if you need to stop the unit for 24h or shorter time This is to heat the crank case heater to avoid the compulsive start of comp...

Page 4: ...ced running mode When protection device is activated running indicator light is lightened and query light flashes Protection device may start under the following circumstances cooling operation The ai...

Page 5: ...oor unit Bad odor Operation lamp flashes No priority of Standby on panel is lightened Thawing frost light flashes in 30s Indoor unit FAN function stop automatically to defrost It is the start and stop...

Page 6: ...presents for a system 1 is A system 2 is B system xL1 DC bus low pressure protection xL2 DC bus high pressure protection xL3 Reserve MCE error synchronization closed loop xL4 Zero speed protection xL5...

Page 7: ...pacity of main mode T4 ambient temp revision of cooling capacity T4 ambient temp revision of heating capacity The outdoor unit actual operation capacity Capacity requirement Speed of fan A Speed of fa...

Page 8: ...te with outdoor unit When it is operating it will display the rotation frequency of the compressor Operation mode 0 Off 2 Cooling 3 Heating 4 Forceing cooling 5 Mixed cooling 6 Mixed Heating Fan speed...

Reviews: