Trane TVR 5G Owner'S Manual Download Page 2

1.    IMPORTANT SAFETY INFORMATION 

To prevent injury to the user or other people and property 
damage, the following  instructions must be followed. Incorrect 
operation due to ignoring of instructions may cause harm or 
damage.  

CAUTION 

Do not use the air conditioner for other purposes. 

 

In order to avoid any quality deterioration, do not use the unit for 
cooling precision instruments, food, plants, animals or works of 
art.  
 

Before cleaning, be sure to stop the operation, turn the 
breaker off or pull out the supply cord. 

 

Otherwise, an electric shock and injury may result.  
 

In order to avoid electric shock or fire, make sure that an 
earth leak detector is installed.

 

 

Be sure the air conditioner is grounded.

  

In order to avoid electric shock, make sure that the unit is 
grounded and that the earth wire is not connected to gas or 
water pipe, lightning conductor or telephone earth wire. 
 

In order to avoid injury, do not remove the fan guard of the 
outdoor unit. 

 

Do not operate the air conditioner with a wet hand. 

 

An electric shock may happen.  
 

Do not touch the heat exchanger fins. 

 

These fins are sharp and could result in cutting injuries. 
 

owner's manual 

  

WARNING 

W ARNING 

CAUTION 

CONTENTS 

PAGE 

IMPORTANT SAFETY INFORMATION...................................................... 
PARTS NAMES........................................................................................ 
OPERATION AND PERFORMANCE........................................................... 
TROUBLES AND CAUSES........................................................................ 
MALFUNCTION....................................................................................... 
CONSTRAINT COOLING AND QUERY....................................................... 
AFTER-SALES SERVICE.......................................................................... 

The safety precautions listed here are divided into two categories. In 
either case, important safety information is listed which must be read 
carefully. 

Failure to observe a warning may result in death. 

Failure to observe a caution may result in injury or damage 
to the equipment. 

Ask your dealer for installation of the air conditioner. 

 

Incomplete installation performed by yourself may result in a 
water leakage, electric shock, and fire.  
 

Ask your dealer for improvement,repair,and maintenance. 

Incomplete improvement, repair, and maintenance may result in 
a water leakage, electric shock, and fire.  
 

In order to avoid electric shock, fire or injury, or if you 
detect any abnormality such as smell of fire, turn off the 
power supply and call your dealer for instructions.

 

 

Never replace a fuse with that of wrong rated current or 
other wires when a fuse blows out. 

 

Use of wire or copper wire may cause the unit to break down or 
cause a fire. 
 

Do not insert fingers, rods or other objects into the air inlet 
or outlet. 

When the fan is rotating at high speed, it will cause injury.  
 

Never use a flammable spray such as hair spray, lacquers 
paint near the unit.

  

It may cause a fire.  
 

Never touch the air outlet or the horizontal blades while the 
swing flap is in operation. 

 

Fingers may become caught or the unit may break down.  
 

Never inspect or service the unit by yourself.

  

Ask a qualified service person to perform this work.  
 
 

Do not dispose this product as unsorted municipal 
waste.Collection of such waste separately for special 
treatment is necessary. 
 
Keep far away from high-frequency equipment. 
 
Keep away from the following places:  

a place where it is full of ail gas; places where salty air 
surrounding(near the coast); a place where is caustic gas(the 
sulfide in hotspring). Location in the folling places may cause 
malfunction or shorten the life span of the manchine. 
 
I

n the case of extremely strong wind, please prevent the air 

from flowing backwards into the outdoor unit. 

 

Snow canopy is necessary in snowfall places on the 
outdoor unit. Please consult the local dealer for details. 

 
I

n the frequent thunderstruck place, lightningproof actions 

should be taken. 
 
To prevent refrigerant leak, contact your dealer. 

 

When the system is installed and runs in a small room, it is 
required to keep the concentration of the refrigerant, if by any 
chance coming out, below the limit. Otherwise, oxygen in the 
room may be affected, resulting in a serious accident.  
 

The refrigerant in the air conditioner is safe and normally 
does not leak.  

If the refrigerant leaks in the room, contact with a fire of a burner, 
a heater or a cooker may result in a harmful gas. 
 

Turn off any combustible heating devices, ventilate the 
room, and contact the dealer where you purchased the unit. 

 

Do not use the air conditioner until a service person confirms 
that the portion where the refrigerant leaks is repaired.  
 

Disposal:Do not dispose this product as unsorted 
municipal waste.Collection of such waste 
separately for special treatment is necessary. 







Summary of Contents for TVR 5G

Page 1: ...DC Inverter Heat Recovery TVR 5G OWNER S MANUAL Thank you very much for purchasing our air conditioner Before using your air conditioner please read this manual carefully and keep it for future refere...

Page 2: ...ealer for instructions Never replace a fuse with that of wrong rated current or other wires when a fuse blows out Use of wire or copper wire may cause the unit to break down or cause a fire Do not ins...

Page 3: ...ioner for at least 12 hours before operation Do not switchoff the power if you need to stop the unit for 24h or shorter time This is to heat the crank case heater to avoid the compulsive start of comp...

Page 4: ...ced running mode When protection device is activated running indicator light is lightened and query light flashes Protection device may start under the following circumstances cooling operation The ai...

Page 5: ...oor unit Bad odor Operation lamp flashes No priority of Standby on panel is lightened Thawing frost light flashes in 30s Indoor unit FAN function stop automatically to defrost It is the start and stop...

Page 6: ...presents for a system 1 is A system 2 is B system xL1 DC bus low pressure protection xL2 DC bus high pressure protection xL3 Reserve MCE error synchronization closed loop xL4 Zero speed protection xL5...

Page 7: ...pacity of main mode T4 ambient temp revision of cooling capacity T4 ambient temp revision of heating capacity The outdoor unit actual operation capacity Capacity requirement Speed of fan A Speed of fa...

Page 8: ...te with outdoor unit When it is operating it will display the rotation frequency of the compressor Operation mode 0 Off 2 Cooling 3 Heating 4 Forceing cooling 5 Mixed cooling 6 Mixed Heating Fan speed...