CNT-PRC003-EN

Figure 3. Tracer VV550/551 wiring diagram

{

{

{

{

3

2

1

On

Cancel

Binary 
input

Trane zone 
sensor

In

Out

Rover 
service tool

Analog inputs

Binary outputs

LonTalk

®

communication 
link

24V

GND

Wiring diagram for Tracer 
VV550/551 VAV controllers

Summary of Contents for Tracer VV550

Page 1: ...CNT PRC003 EN October 2005 Tracer Controls Tracer VV550 551 VAV Controllers...

Page 2: ...other manufacturer or as a standalone device When it is part of a Trane ICS a Tracer VV550 551 VAV controller enables the building automation system BAS to perform functions such as scheduling trendin...

Page 3: ...Auto commissioning sequence 5 Manual test function 5 Drive minimum and maximum from zone sensor 5 Trane controller compatibility 5 Interoperability 5 Wiring diagram 5 Wiring diagram for Tracer VV550...

Page 4: ...to a floor area With this feature the installer can quickly configure the flow control boxes and set up the system without the need for custom programming Local versus remote reheat flexibility Tracer...

Page 5: ...hat includes a thumbwheel setpoint a Tracer VAV VV550 551 controller can easily be overridden to minimum and maximum flow By simply turning the thumbwheel to the controller drives the air valve to the...

Page 6: ...3 Tracer VV550 551 wiring diagram 3 2 1 On Cancel Binary input Trane zone sensor In Out Rover service tool Analog inputs Binary outputs LonTalk communication link 24V GND Wiring diagram for Tracer VV...

Page 7: ...nication link Figure 4 Cancel ON 85 80 75 70 65 60 55 50 o o o TM ROVER Cancel ON 85 80 75 70 65 60 55 50 Cancel ON 85 80 75 70 65 60 55 50 Figure 4 Network architecture with Tracer VV551 VAV controll...

Page 8: ...e 5 Contact your Trane sales office about other compatible zone sensors Figure 5 Zone sensors for use with Tracer VV550 551 GCC order number Zone Timed override buttons LCD Comm jack Setpoint thumbwhe...

Page 9: ...stor 10 k 77 F 25 C From 14 to 122 F 10 to 50 C Space setpoint potentiometer 1 k From 50 to 90 F 10 to 32 2 C Primary discharge air temperature thermistor 10 k 77 F 25 C From 40 to 212 F 40 to 100 C P...

Page 10: ...10 CNT PRC003 EN Figure 6 Tracer VV551 dimensions 7 5 in 19 2 cm 6 5 in 16 7 cm 6 5 in 16 7 cm 7 5 in 19 2 cm 5 5 in 14 0 cm Cover off Cover on...

Page 11: ...nvoStatus SNVT_obj_status Space CO2 nviSpaceCO2 SNVT_ppm Alarm message nvoAlarmMessage SNVT_str_asc Clear alarms diagnostics nviRequest SNVT_obj_request Part of the node object Air flow setpoint input...

Page 12: ...and specifications without notice Literature Order Number CNT PRC003 EN File Number PL ES CNT PRC003 1005 Supersedes CNT PRC003 EN April 2004 Stocking Location Inland Trane A business of American Stan...