RLC-SVU007D-GB
4
4
UNT-PRC002-GB
Technical Data
FWD
08
12
20
30
45
Power supply
(V/Ph/Hz)
230/1/50
Capacities
Cooling capacity on water (1)
(kW)
5,2
8,3
15
18,8
30,1
Heating capacity on water (2)
(kW)
6,3
11,9
18,9
20,9
38,2
Fan motor
(type)
2 x direct drive centrifugal
Fan power input (3)
(kW)
0,23
0,46
0,65
1,04
1,51
Current amps (3)
(A)
1,1
2,2
3,1
4,7
5,5
Start-up amps
(A)
3,2
5,5
9,3
14,1
16,5
Air flow
minimum
(m
3
/h)
490
980
1400
1800
2700
nominal
(m
3
/h)
820
1650
2300
3000
4500
maximum
(m
3
/h)
980
1970
2600
3600
5400
Main coil
Water entering/leaving connections
(type)
ISO R7 rotating female
(Dia)
3/4"
3/4"
1 1/2"
1 1/2"
1 1/2"
Electric heater (accessory for blower only)
Electric power supply
(V/Ph/Hz)
230/1/50
230/1/50 or 400/3/50
400/3/50
400/3/50
400/3/50
Heating capacity
(kW)
2/4
8
10
12
12
Hot water coil (accessory for blower only)
Heating capacity (4)
(kW)
6,3
12
17,4
22,4
34,5
G2 filter (filter box accessory)
Quantity
2
2
2
2
2
Dimensions ( LxWxth)
(mm)
386x221x8
486x271x8
586x321x8
586*421*8
586*621*8
G4 filter (filter box accessory)
Quantity
-
2
2
2
2
Dimensions ( LxWxth)
(mm)
-
486x264x48
586x314x48
586*414*48
586*614*48
Condensate pump (accessory)
(type)
Centrifugal
Water flow - lift height
(l/h - mm)
24 - 500
Not available for FWD30 and FWD45
Sound level (L/M/H speed)
Sound pressure level (5)
(dB(A))
36/40/43
38/41/44
46/50/53
47/52/57
47/52/58
Sound power level (5)
(dB(A))
46/50/53
48/51/54
56/60/63
57/62/67
57/62/68
Unit dimensions
Width x Depth
(mm)
890 x 600
1090 x 710
1290 x 820
1290 x 970
1290 x 1090
Height
(mm)
250
300
350
450
650
Shipped unit dimensions
Width x Depth
(mm)
933 x 644
1133 x 754
1333 x 864
1333 x 1008
1333*1133
Height
(mm)
260
310
360
460
660
Weight
(kg)
32
46
61
76
118
Colour
galvanised steel
Recommended fuse size
Unit alone (aM/gI)
(A)
8/16
8/16
8/16
8/25
8/25
Unit with electric heater (gI)
(A)
16 (2kW),25 (4kW)
40 (230V),3*16 (400V)
3*20
3*25
3*25
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.
Heat exchanger operating limits:
FWD:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars
Accessories - Hot water coil:
*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars
Installer-Supplied Components / Interconnecting Wiring
Installer-Supplied Components
Customer wiring interface connections are shown in the
electrical schematics and connection diagrams that are
shipped with the unit. The installer must provide the
following components if not ordered with the unit:
• Power supply wiring (in conduit) for all field-wired
connections.
• All control (interconnecting) wiring (in conduit) for
field supplied devices.
• Fused-disconnect switches or circuit breakers.
Interconnecting Wiring
Chilled Water Pump Control
NOTICE:
Equipment Damage!
If the microprocessor calls for a pump to start and
water does not flow, the evaporator may be damaged
catastrophically. It is the responsibility of the installing
contractor and/or the customer to ensure that a pump
will always be running when called upon by the chiller
controls.
An evaporator water pump output relay closes when
the chiller is given a signal to go into the Auto mode
of operation from any source. The contact is opened to
turn off the pump in the event of most machine level
diagnostics to prevent pump overheat.
The relay output is required to operate the Evaporator
Water Pump (EWP) contactor. and Heat recovery Water
Pump (HRWP) (multipipe unit) Contacts should be
compatible with 115/240 VAC control circuit. Normally,
the EWP/HRWP relay follows the AUTO mode of the
chiller. Whenever the unit has no diagnostics and is in
the AUTO mode, regardless of where the auto command
is coming from, the normally open relay is energized.
When the unit exits the AUTO mode, the relay is timed to
open in an adjustable (using TU or TD7) 0 to 30 minutes.
The non-AUTO modes, in which the pumps are stopped,
includes Reset, Stop, External Stop, Remote Display
Stop, Stopped by Tracer, Start Inhibited by Low Ambient
Temp, and Ice Making complete (if applicable).
Table 2 - Pump relay operation
Chiller Mode
Relay Operation
Auto
Instant Close
Ice Making
Instant Close
Tracer Override
Close
Stop
Timed Open
Ice Complete
Instant Open
Diagnostics
Instant Open
When going from Stop to Auto, the Evaporator Water
Pump relay is energized. Water flow switch is activating,
and flow status information back after 15 seconds.
Pump relay Operation for multi-pipe unit
Priority mode
Evaporator
Heat Recovery
Pump command
Pump command
Cooling Only
Active
OFF
Heating Only
OFF
Active
Cooling Priority
Active
Active
Heating Priority
Active
Active
Heat Recovery Priority
Active
Active
Max Capacity Priority
Active
Active
Unit mode
Evaporator or Heat recovery Pump Relay
Auto
Active
Tracer Override
OFF
Stop
Active
Diagnostic
Active