background image

5

A70 UG 007 E - 0299

KEY 

/

(Outdoor temp. option):

When the outdoor temperature
option is connected to your thermo-
stat, you can display this value by
pressing the  

/

key. If this

option is not connected, the thermo-
stat displays “- -“

KEY / 

(Day/Night):

When the thermostat is initialised,
the symbol 

corresponding to the

day-time temperature is displayed.
By pressing the 

/

key or pow-

ering up the CLK1 and CLK2 termi-
nals at the back of the thermostat
(customer connection), you can
select a relief or night-time tempera-
ture 

. (The thermostat memorises

this temperature).
To alternate between the two tem-
perature settings simply press the

key.

CLOCK TERMINALS (option):
CLK1 - CLK2

If you connect a clock to these termi-
nals, the thermostat can alternate
automatically between the day/night
set point values.

REMOTE SENSOR TERMINALS
(option):
RS1-RS2-RS+V

The THS thermostat is designed to
accept an electronic remote sensor
that will enable you to place the ther-
mostat in an unobtrusive position. 

°C/°F

Press the 

and 

keys simulta-

neously to change the °C /°F display.

Power cuts

One of this thermostat’s special fea-
tures is that it does not need a bat-
tery to conserve the selected set
points if a power cut occurs. Its
memory is not affected by power
cuts, no matter how long they last.
When the current returns, the ther-
mostat will continue to operate as if
the power had never been discon-
nected.

Temperature precision

The thermostat will measure the
temperature exactly once it has been
installed and powered up for at least
one hour.

Summary of Contents for THS-02

Page 1: ...THS 02 Thermostat for heat pump 2 com pressors with auxiliary heating User s guide A70 UG 007 GB...

Page 2: ...2 A70 UG 007 E 0299 American Standard Inc 1999...

Page 3: ...tions 4 General information 4 User commands 4 Power cuts 5 Temperature precision 5 Installation instructions 6 Position 6 Removing the thermostat from its base 6 Setting the micro switches 7 Replacing...

Page 4: ...commands MODE Select the operating mode you want by pressing the MODE key several times controls the system in cooling mode only the word COOL is displayed for 5 seconds controls the system in heatin...

Page 5: ...If you connect a clock to these termi nals the thermostat can alternate automatically between the day night set point values REMOTE SENSOR TERMINALS option RS1 RS2 RS V The THS thermostat is designed...

Page 6: ...er nal doors Places where the presence of water or steam piping hot air ducts or an unoccupied room behind the ther mostat may affect its operation Near to a unit s air discharge grille Near to source...

Page 7: ...a ture is within 0 5 C of the set point Forced heating is never autho rised Replacing thermostat on its base 1 Position the thermostat on the hinge lugs located on top of the base 2 Slowly lower the t...

Page 8: ...W1 Y2 B O b c d f h W1 Y1 R 24 V G O B Y2 LED1 LED2 RS V RS1 RS2 CLK2 CLK1 a a Compressor 2 b Auxiliary heating c Compressor 1 d Fan e Common f Independent power supply g Mains power supply h 24 V tr...

Page 9: ...te 1 The R terminal can be used for a second independent power supply If there is just one power supply bridging is provided between 24V and R Note 2 This thermostat can operate using 24VD C The negat...

Page 10: ...10 A70 UG 007 E 0299 Notes...

Page 11: ...11 A70 UG 007 E 0299 Notes...

Page 12: ...cation Europe Trane reserves the right to alter any information without prior notice For additional information contact Distributor Installer stamp The constructor s policy is one of continuous produc...