34
TK 56460-19-OP-EN
Specifications
Electrical Control System
Control System
Voltage
12 Vdc
Batteries
TriPac Envidia Battery Box: Four Thermo King NXT, AGM, Deep Cycle
Truck Battery Box: Four, Group 31, 1150 CCA Minimum, (Thermo King
NXT Recommended)
Alternator
Truck mounted, 12 V, 270 amp minimum required (300 amp
recommended)
Fuses
Fuse
Num-
ber
Location
Amp
Rat-
ing
Component Protected/
Circuit - Connector
F1
Base Controller Fuse Panel
20
Heater/HTR1
F2
Base Controller Fuse Panel
15
Condenser Fan/CFPOS
F3
Base Controller Fuse Panel
15
Evaporator Fan/EFPOS
F4
Base Controller Fuse Panel
5
Controller/2F
F5
Base Controller Fuse Panel
2
HMI/2P
F6
Base Controller Fuse Panel
2
HMI/8XP
F7
Heater Harness
5
Heater/RED
F8
Vehicle Ignition Harness
1
Ignition Input/IGN
F9
Fuse Block in Battery Box
60
Smart Charger 2/2C
F10
Fuse Block in Battery Box
150
Compressor Drive Module
(CDM)
F11
Fuse Block in Battery Box
40
Base Controller/2
F12
Fuse Block in Battery Box
60
Smart Charger 1/2B
F13
Fuse Holder in Positive Battery
Harness
175
Truck Batteries/RED
F14
Fuse Holder in Positive Inverter/
Converter Harness
150
Inverter/Converter/RED