5. Insert doubled over end of resistance wire into drain, Tee, or 90 degree connector ((D
De
etta
aiill IIV
V)) and then into
crossover drain tube ((D
De
etta
aiill V
V)).
N
No
otte
e:: The use of either white or blue drain tubes is acceptable when interconnecting multiple evaporators.
6. Attach drain Tee or 90 degree connector to evaporator drain tube and push connector on firmly to engage O-ring
((D
De
etta
aiill V
VII)).
IV
V
VI
RCS1148
7. Pull resistance wire through interconnecting drain tube as far as possible and make sure it is not bunched up ((D
De
etta
aiill
V
VIIII)).
8. Insert other resistance wire into other drain Tee connector and as shown ((D
De
etta
aiill V
VIIIIII)).
IIm
mp
po
orrtta
an
ntt:: At no time should resistance wires from one side of the drain pan overlap the resistance wires from the
other side.
9. Attach interconnecting drain tube to opposite Tee connector by pushing Tee connector on firmly to engage O-ring
((D
De
etta
aiill IIX
X)).
VIII
IX
VII
RCS1149