824 Programmable Wi-Fi Comfort Control
18-HD72D1-6
29
5.4.5 Group 5 Comfort Settings
MENU ITEM
OPTIONS [DEFAULT]
DESCRIPTION
Enable Dehumidification
[Enable], Disable
Select if enhanced dehumidification features are enabled. See section
7.2 Advanced Operation - Dehumidification for additional information.
Dehumidification Overcooling Limit - Degrees
[0°] to 3°F
Select the maximum amount of overcooling allowed when the indoor
humidity exceeds the cooling target humidity setpoint. See section 7.2
Advanced Operation - Dehumidification for additional information.
Smart Continous Fan
Enable, [Disable]
Select to enable or disable Smart Continous Fan
Control Response Rate
[Normal], Fast
Select the response rate of the control. See section 7.1 Advanced
Operation - Control Response Rate for additional information.
Aggressive Recovery > 2° Setpoint Change
Enable, [Disable]
Select whether the 10-minute staging inhibit is disabled (heating or
cooling mode) with a setpoint change greater than 2°. See section
7.7.1 Advanced Operation - Aggressive Recovery for additional
information.
Heating Aggressive Recovery by Outdoor
Temperature
Enable, [Disable]
Select whether the 10-minute staging inhibit is disabled during heating
mode when the outdoor temperature falls below the selected outdoor
temperature (Outdoor temperature sensor must be connected and
enabled to allow this setting to be selected)
Heating Aggressive Recovery
Setting
0° to 70°F [40°F]
Select the outdoor temperature for Heating Aggressive Recovery
Warm Air Discharge
Enable, [Disable]
When enabled the indoor airflow will be limited to 80% on a call for
heat pump heating. This only applies to heat pump heating with no call
for aux heat (An indoor unit with a variable speed blower is required)