Part No. 37-7760003
09-2018 18-HD48D1-1A-EN 9
Trane XR302 and XR303 Touchscreen Thermostat
O
Y2
Y1
G
R
B
W2
W1
O
Y2
Y/Y1
R
B
X2
O/B
L
Y2
Y
G
Rc
Rh
C
+
S
-
HM
W2
W/E
6
DHM
Optional
remote
indoor or
outdoor
wired
sensor
FOOTNOTES:
1) A/TCONT302 {does not include humidifier(HM) and dehumidifier(DHM) terminals}
2) Wire third party condensate overflow switches between Y of the thermostat and Y1
of the airflow control board
3) X2 is required for aux heat signal during defrost
4) Factory installed jumper
1 or 2 Stage Heat Pump with Variable Speed Furnace
* Caution: Do not run Outdoor/Remote sensor wires
in the same bundle with HVAC wires. Also, keep
away from high voltage wiring to avoid interference.
Thermostat
Thermostat
Indoor Unit
Outdoor Unit
1
2
4
3
1