CAUTION!
The thermostat must not be left unsupervised
when open. (Prevent non specialists and especially
children from gaining access to it.)
Only qualified electricians or authorised service
staff are permitted to open the thermostat.
If the thermostat is used in a way not specified by
the manufacturer, its safety may be impaired.
Operating Instructions
Page 1 of 3
RFRP Room Thermostat
Wireless
4. Installation
1. Factory default settings
6. LCD Symbol / button description
5. Frost protection
2. Specifications & wiring
Temperature indicator:
°C
Switching differential:
0.4°C
In built frost protection:
5°C - Not adjustable
Clock:
24 hours
Keypad lock:
Off
Operating mode:
5/2 day
5°C
Manual
mode
Off mode
Program mode
Set Date/ Time
Holiday mode
Copy function
Boost mode
Automatic
mode
(Back)
OK confirm button
Set point increase
Set point decrease
Reset button
Operating mode
Current program
Day / Month
Day of the week
Temperature
Battery low symbol
Wireless symbol
Heating on symbol
Keypad lock symbol
Wireless connect button
Current Time
(Boost to time)
3. Mounting
Contents
1. Factory default settings
2. Specifications & wiring
3. Mounting
4. Installation
5. Frost protection
6. LCD symbol / buttons description
7. Resetting the thermostat
8. Keypad lock and unlock
9. Setting the date, time and operating mode
10. Factory program settings
11. Adjusting the program settings for 5/2d
12. Copy Function
13. Temporary override
14. Permanent override
15. Boost function
16. Holiday function
17. To connect the RFRP thermostat to an RF1A receiver
18. To disconnect the RFRP thermostat from an RF1A receiver
19. Backlight mode selection
20. Battery low warning
21. Replacing the batteries
Prior to setting the thermostat, it is neccessary to
complete all required settings described in this section.
6.1 LCD Symbol description
6.2 Button description
Important: Keep this document
Power supply:
2 x AA Alkaline Battery
Power consumption:
2 mW
Battery replacement:
Once a year
Temp. control range:
5 ... 35°C
Ambient temperature:
0 ... 50°C
Dimensions:
130 x 99 x 25mm
Temperature sensor:
NTC 10K Ohm @ 25°C
Temperature indication:
˚C
Switching differential:
0.4˚C
Frost protection:
Only operational in OFF mode
20170816_RFRP_OpI
ns_JW
EPH Controls Ireland
Sitecast Industrial Estate, Pouladuff,
Cork, T12 W665, Ireland
[email protected] www.ephcontrols.com
EPH Controls UK
Unit E4, Welland Business Park, Valley Way, Market Harborough,
Leicestershire, LE16 7PS, United Kingdom
[email protected] www.ephcontrols.co.uk
The mounting height should be 1.5 meters above the floor level.
The thermostat should be wall mounted in the room where the heating is to
be controlled.
The place of installation should be chosen so that the sensor can measure the
room temperature as accurately as possible.
Choose the mounting location to prevent direct exposure to sunlight or other
heating / cooling sources when mounted.
The unit can be fitted to:
1. Recessed conduit boxes.
2. Directly on walls.
3. Table mounting with stand provided.
Frost protection is built into this thermostat.
It is pre fixed at 5°C and is not adjustable.
It will only be activated when the thermostat is in the OFF mode and the
room temperature falls below 5°C.
Lower the flap at the front of the thermostat.
There is a battery compartment located below the buttons.
Using your 2 thumbs, apply pressure and pull downwards to remove the cover.
Insert the 2 x AA batteries and the thermostat will turn on.
Close the battery compartment.
AUTO
MAN
OFF
PROG
TIME
HOL
COPY
BOOST
OK