RT-SVX38C-EN
5
Model Number Description
Digit 1—Unit Type
T
DX cooling
Y
DX cooling, gas heat
W Packaged heat pump
Digit 2—Efficiency
S
Standard Efficiency
Digit 3—Airflow
C
Convertible
Digit 4,5,6—Nominal Gross
Cooling Capacity (MBh)
060
5 ton (17.6 kW)
072
6 ton (21.1 kW)
090
7½ ton (26.4 kW)
102
8½ ton (29.9 kW)
120
10 ton (35.1 kW)
Digit 7—Major Design Sequence
E
R-410A refrigerant
Digit 8—Voltage Selection
D
380-415/50/3
Digit 9—Unit Controls
R
ReliaTel™ microprocessor
K
European
Digit 10—Heating Capacity
0
No electric heat
7
L
Low heat
8
H
High heat
8
Digit 11—Minor Design
Sequence
A
First sequence
Digit 12,13—Service Sequence
** Factory assigned
Digit 14—Fresh Air Selection
0
No Fresh air
A
Manual outside air damper 0–50%
1
B
Motorized Outside air damper 0–50%
C
Economizer, dry bulb 0–100%
without barometric relief
4
D
Economizer, dry bulb 0–100% with
barometric relief
4
E
Economizer, reference enthalpy
0-100% without barometric relief
3
,
4
F
Economizer, reference enthalpy
0-100% with barometric relief
3
,
4
G
Economizer, comparative enthalpy
0–100% without barometric relief
3
,
4
H
Economizer, comparative enthalpy
0–100% with barometric relief
3
,
4
Digit 15—Supply Fan/Drive Type/
Motor
0
Standard drive
3
1
Oversized motor
Digit 16—Hinged Service
Access/Filters
0
Standard panels/standard filters
A
Hinged access panels/standard
filters
B
Standard panels/2" MERV 8 filters
C
Hinged access panels/2" MERV 8
filters
D
Standard panels/2" MERV 13 filters
E
Hinged access panels/2" MERV 13
filters
Digit 17—Condenser Coil
Protection
0
Standard coil
1
Standard coil with hail guard
2
Black epoxy pre-coated condenser
coil
3
Black epoxy pre-coated
Condenser coil with hail guard
4
CompleteCoat™ condenser coil
9
5
CompleteCoat™ condenser coil with
hail guard
9
Digit 18—Through the Base
Provisions
0
No through-the-base provisions
Digit 19—Disconnect/Circuit
Breaker (three-phase only)
0
No disconnect/no circuit breaker
Digit 20—Convenience Outlet
0
No convenience outlet
Digit 21—Communications
Options
0
No communications interface
1
Trane communications interface
2
LonTalk® communications interface
Digit 22—Refrigeration System
Option
0
Standard refrigeration system
5
Digit 23—Refrigeration Controls
Note:
Applicable to digit 7 = E
0
No refrigeration control
2
1
Frostat™
6
Digit 24—Smoke Detector
0
No smoke detector
Digit 25—System Monitoring
Controls
0
No monitoring control
1
Clogged filter switch
2
Fan failure switch
3
Discharge air sensing tube
4
Clogged filter switch and fan failure
switch
5
Clogged filter switch and discharge
air sensing tube
6
Fan failure switch and discharge air
sensing tube
7
Clogged filter switch, fan failure
switch and discharge air sensing
tube
A
Condensate drain pan overflow
switch
B
Clogged filter switch and condensate
drain pan overflow switch
C
Fan failure switch and condensate
drain pan overflow switch
D
Discharge air sensing and
condensate drain pan overflow
switch
E
Clogged filter switch, fan failure
switch and condensate drain pan
overflow switch
F
Clogged filter switch, discharge air
sensing tube and condensate drain
pan overflow switch
G
Fan failure switch, discharge air
sensing tube and condensate drain
pan overflow switch
H
Clogged filter switch, fan failure
switch, discharge air sensing and
condensate drain pan overflow
switch
Digit 26—System Monitoring
Controls
0
No monitoring controls
A
Demand control ventilation (CO
2
)
10
Digit 27—Unit Hardware
Enhancements
0
No enhancements
1
Stainless steel drain pan
Model Number Notes
1.
Manual outside air damper will ship
factory supplied within the unit, but
must be field installed.
2.
High pressure control crankcase
heaters are standard on all units.
3.
Belt drive is standard on all units.
4.
Economizer with barometric relief is
for downflow configured units only.
Order economizer without barometric
relief for horizontal configuration.
Barometric relief for horizontal
configured units must be ordered as
field-installed accessory.
5.
Standard metering devices are TXVs.
6.
Frostat is available as
factory-installed option only.
7.
Electric heaters are available only for
field-installed options.
8.
Available only for gas heat models.
9.
Not available on heat pumps.
10. Demand control ventilation option
includes wiring only. The C0
2
sensor
is a field-installed only option.
Y
S
C
0
6
0
E
3
R
L
A
*
*
1
2
3
4
5
6
7
8
9
10
11
12
13
Summary of Contents for RT-SVX38C-EN
Page 26: ...Installation 26 RT SVX38C EN Figure 28 Examples...
Page 45: ......
Page 46: ......
Page 47: ......