15
RT-PRC017-EN
Table PD-2 - Gross Cooling Capacities (kW) - YSC072AD - (SI)
Ambient Temperature (C)
Enter.
30
35
40
45
Dry
Bulb
Entering Wet Bulb Temperature (C)
m
3
/h
Temp
16
19
22
16
19
22
16
19
22
16
19
22
Airflow
(C)
TGC SHC
TGC SHC TGC SHC
TGC
SHC
TGC SHC TGC SHC
TGC SHC TGC SHC
TGC SHC
TGC SHC
TGC SHC
TGC SHC
24
20.9 17.5
23.3 14.6 24.6 10.3
19.7
16.8
22.4 13.6 24.0
9.9
18.4 16.1 21.2 12.9
23.2
9.4
17.1 15.4
19.7 12.9
22.0
9.0
3670
27
21.6 21.2
23.4 17.4 24.8 13.5
20.4
20.4
22.5 17.0 24.1 13.3
19.4 19.4 21.2 16.4
23.3 12.8
18.2 18.2
19.8 15.7
22.1 12.3
30
22.9 22.9
23.6 20.6 25.0 16.5
22.1
22.1
22.7 20.4 24.3 16.3
21.0 21.0 21.5 19.9
23.5 16.1
19.9 19.9
20.2 19.2
22.2 15.6
33
24.0 24.0
24.1 23.8 25.2 19.4
23.4
23.4
23.3 23.3 24.5 19.3
22.5 22.5 22.4 22.4
23.6 19.3
21.4 21.4
21.4 21.4
22.3 18.8
24
21.5 18.5
23.6 15.2 24.8 10.6
20.3
17.9
22.8 14.2 24.2 10.1
19.0 17.2 21.6 13.6
23.4
9.8
17.6 16.4
20.1 12.9
22.3
9.3
4080
27
22.3 22.3
23.8 18.1 25.1 14.5
21.3
21.3
22.9 17.9 24.3 13.6
20.2 20.2 21.6 17.3
23.6 13.4
19.0 19.0
20.2 16.6
22.4 12.8
30
23.6 23.6
24.0 21.6 25.3 17.6
22.9
22.9
23.2 21.5 24.6 16.8
21.8 21.8 22.0 21.1
23.7 16.7
20.7 20.7
20.8 20.5
22.5 16.3
33
24.6 24.6
24.6 24.6 25.5 20.0
23.9
23.9
23.9 23.9 24.8 20.1
23.1 23.1 23.1 23.1
23.9 20.1
22.1 22.1
22.1 22.1
22.7 19.8
24
22.0 19.5
23.9 15.8 25.0 10.7
20.8
18.9
23.1 14.7 24.4 10.4
19.5 18.2 21.9 14.2
23.5 10.1
18.1 17.4
20.5 13.5
22.5
9.6
4490
27
22.9 22.9
24.0 18.7 25.3 13.9
22.1
22.1
23.2 18.6 24.5 13.9
20.9 20.9 22.0 18.2
23.7 13.6
19.7 19.7
20.6 17.6
22.6 13.3
30
24.1 24.1
24.3 22.4 25.5 17.4
23.4
23.4
23.5 22.4 24.8 17.3
22.5 22.5 22.5 22.2
23.9 17.2
21.3 21.3
21.3 21.3
22.8 17.0
33
25.0 25.0
25.0 25.0 25.7 20.7
24.4
24.4
24.4 24.4 25.1 20.8
23.7 23.7 23.7 23.7
24.2 20.8
22.6 22.6
22.6 22.6
23.1 20.7
24
22.4 20.3
24.1 16.3 25.2 10.9
21.2
19.8
23.2 15.1 24.5 10.7
19.9 19.1 22.2 14.7
23.6 10.3
18.5 18.4
20.8 14.0
22.7
9.9
4900
27
23.4 23.4
24.3 19.3 25.5 14.5
22.6
22.6
23.4 19.2 24.7 14.7
21.5 21.5 22.3 19.0
23.8 14.0
20.3 20.3
20.9 18.4
22.8 13.7
30
24.5 24.5
24.6 23.2 25.6 17.8
23.8
23.8
23.9 23.2 25.0 17.8
23.0 23.0 23.0 23.0
24.1 17.7
21.8 21.8
21.8 21.8
23.0 17.7
33
25.4 25.4
25.4 25.4 25.9 21.2
24.8
24.8
24.8 24.8 25.3 21.4
24.1 24.1 24.1 24.1
24.4 21.4
23.1 23.1
23.1 23.1
23.4 21.6
Notes:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling, subtract indoor fan heat.
2. TGC = Total Gross Capacity
3. SHC = Sensible Heat Capacity
Performance
Data
Table PD-2a _ Gross Cooling Capacities (MBH) - YSC072AD - (IP)
Ambient Temperature (F)
Enter.
85
95
105
115
Dry
Bulb
Entering Wet Bulb Temperature (F)
CFM
Temp
61
67
73
61
67
73
61
67
73
61
67
73
Airflow
(F)
TGC SHC
TGC SHC TGC SHC
TGC
SHC
TGC SHC TGC SHC
TGC SHC TGC SHC
TGC SHC
TGC SHC
TGC SHC
TGC SHC
75
72.2 59.1
80.6 47.1 85.1 31.0
67.5
56.5
77.7 44.1 82.7 29.6
62.6 53.9 73.0 41.8
79.9 28.0
57.4 51.2
67.5 39.2
75.5 26.0
2160
80
73.8 70.7
81.0 56.1 85.8 42.2
69.4
68.2
77.9 55.0 83.4 40.7
65.0 65.0 73.1 52.6
80.4 39.0
60.6 60.6
67.6 50.0
75.8 36.8
85
77.7 77.7
81.4 66.3 86.3 51.7
74.3
74.3
78.2 65.6 83.8 50.1
70.3 70.3 73.6 63.5
80.7 49.2
66.0 66.0
68.3 61.0
76.1 47.4
90
81.3 81.3
82.4 76.3 87.1 59.8
78.8
78.8
79.4 76.0 84.6 59.4
75.1 75.1 75.3 74.6
81.3 59.0
70.8 70.8
70.7 70.7
76.6 57.4
75
74.2 62.5
81.6 49.2 85.7 31.5
69.3
59.9
78.7 46.0 83.4 30.1
64.4 57.3 74.2 43.7
80.2 28.5
59.1 54.6
68.9 41.1
76.3 26.6
2400
80
76.1 75.0
82.1 58.2 86.5 43.7
72.1
72.1
79.0 57.4 84.2 42.1
67.9 67.9 74.4 55.4
80.9 40.4
63.3 63.3
69.0 53.0
76.8 38.4
85
80.0 80.0
82.6 69.1 86.8 52.8
77.1
77.1
79.5 68.7 84.7 51.6
73.1 73.1 75.3 67.3
81.4 50.7
68.7 68.7
70.1 65.0
77.2 49.4
90
83.3 83.3
83.8 79.7 87.1 61.5
80.7
80.7
80.9 79.4 85.5 61.5
77.5 77.5 77.5 77.5
82.1 61.1
73.3 73.3
73.3 73.3
77.8 60.2
75
75.8 65.6
82.3 50.7 86.2 32.0
71.0
63.2
79.4 49.8 84.0 30.7
66.0 60.6 75.4 45.6
80.7 29.0
60.6 57.8
70.0 42.9
77.0 27.2
2640
80
78.1 78.1
82.9 60.1 87.2 44.1
74.6
74.6
79.8 59.4 84.7 44.3
70.3 70.3 75.6 58.1
81.2 41.3
65.7 65.7
70.1 55.7
77.6 39.8
85
81.7 81.7
83.6 71.6 88.2 54.0
79.1
79.1
80.5 71.3 85.4 53.6
75.4 75.4 76.6 70.7
82.0 52.1
70.9 70.9
71.6 68.7
78.1 51.3
90
84.8 84.8
85.0 82.5 89.1 62.3
82.3
82.3
82.3 82.3 86.1 61.2
79.4 79.4 79.4 79.4
82.8 63.0
75.2 75.2
75.2 75.2
78.7 62.8
75
77.0 68.3
82.9 52.2 86.6 32.5
72.5
66.4
80.0 51.4 84.5 31.2
67.5 63.7 76.2 47.1
81.2 29.5
62.1 61.0
70.8 44.7
77.6 27.8
2880
80
79.6 79.6
83.7 61.8 87.6 44.7
76.6
76.6
80.6 61.3 85.4 44.0
72.4 72.4 76.5 60.5
81.8 42.1
67.7 67.7
71.1 58.2
78.1 40.9
85
83.0 83.0
84.4 73.9 88.7 54.9
80.4
80.4
81.5 73.9 86.2 54.1
77.1 77.1 77.8 73.8
82.7 53.5
72.7 72.7
72.9 71.9
78.8 53.0
90
85.9 85.9
86.0 85.0 89.6 65.2
83.6
83.6
83.6 83.6 87.0 63.2
81.0 81.0 81.0 81.0
83.5 65.0
76.8 76.8
76.8 76.8
79.5 65.3
Notes:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling, subtract indoor fan heat.
2. TGC = Total Gross Capacity
3. SHC = Sensible Heat Capacity