PTAC-PRC001-EN

Model
Number
Description

Digits 1,2  — Packaged Terminal

 Air Conditioner

Digit 3 — Product Type

E = Air Conditioner
H = Heat Pump

Digit 4 — Development Sequence

C = Third Development

Digits 5,6,7 — Unit Cooling Capacity

070 = 7,000 Btu
090 = 9,000 Btu
120 = 12,000 Btu
150 = 15,000 Btu

Digit 8 — Main Power Supply

1 = 208-230/60/1
2 = 265/60/1

Digit 9 — Electric Heating Capacity**

0 = No Electric Heat – Air Conditioners Only
E = 2.5 kW
G = 3.5 kW (208-230V)
G = 3.7 kW (265V)
J = 5.0 kW*

Digit 10 — Design Sequence

Digit 11— Miscellaneous

A = Standard
B = Power Vent
C = Corrosion Resistant
D = Condensate Pump
H = Hydronic Chassis
F = Hydronic with Power Vent and Door
G = Hydronic with Power Door
J = Power Door
K = Condensate Pump with Power Vent
L = Condensate Pump with Power Door

    

Stock Style Models

PTEC0701GCA
PTEC0901GCA
PTEC1201GCA

PTEC1501GCA
PTEC1501JCA

PTHC0701GCA
PTHC0901GCA
PTHC1201GCA

MODEL NOMENCLATURE

PT   E   C   090   1   G   *   A

Notes:
1. Corrosion resistant, condensate pump, power vent units and all special units require extended ship cycles.
2. Only the following units are available from stock and can normally ship within 3 days after release.
3. Contact your local Trane representative for current stock availability and information on minimum quantity
requirements and shipping schedule for special production units.

PTHC1501GCA
PTHC1501JCA

PTEC0902GCA
PTHC0902GCA
PTEC1202GCA
PTHC1202GCA
PTEC1502GCA
PTHC1502GCA

*Sizes 09, 12 and 15 only.
**All heat pump units must have electric coils.

Summary of Contents for Packaged TerminalAir Conditioners & Heat Pumps

Page 1: ...PackagedT erminalAir Conditioners Heat Pumps PTAC PRC001 EN October 2000...

Page 2: ...oners PTACs and heat pumps are ideally suited for offices apartments hotels motels and institutional homes Key benefits which make the units a wise choice are Energy efficiency Reliability Quiet opera...

Page 3: ...efits Application Considerations Selection Procedure Model Number Description Performance Data Cool and Heat Performance Electric Power Power ConnectionWiring Dimension andWeights Mechanical Specifica...

Page 4: ...mperatures of 40 F or below the unit activates the fan motor and either the electric resistance heater or the hydronic heater to help prevent pipes or fixtures from freezing This also overrides front...

Page 5: ...seven inch depth one of the shallowest silhouettes in the industry today To inhibit tampering the front can be secured to the chassis with hidden screws Our unit s new stylish design and neutral color...

Page 6: ...nelWall Installation PanelWall and BlockVeneer Installation On applications not requiring subbase or leveling legs unit may be flush mounted to floor Sleeve Installation Data Framing forWall Case Fram...

Page 7: ...Door G Hydronic with Power Door J Power Door K Condensate Pump with PowerVent L Condensate Pump with Power Door Stock Style Models PTEC0701GCA PTEC0901GCA PTEC1201GCA PTEC1501GCA PTEC1501JCA PTHC0701G...

Page 8: ...05 1110 1120 1120 1485 1505 1505 EER 11 5 11 5 11 5 11 2 11 2 11 2 10 7 10 7 10 7 9 3 9 3 9 3 Unit without Electric Heater Min Circuit Ampacity 2 4 4 0 4 0 3 6 5 1 5 1 4 4 7 3 7 3 5 7 8 4 8 4 7 4 cfm...

Page 9: ...3 2 3 2 3 2 3 1 3 1 3 1 2 8 2 8 2 8 2 42 5500 5700 5700 7200 7300 7300 9800 10000 10000 12200 12300 12300 37 4900 5100 5100 6400 6500 6500 9000 9200 9200 11200 11300 11300 32 4300 4500 4500 5600 5700...

Page 10: ...55 3280 34 8935 3060 34 73 80 10585 4790 45 10020 4580 46 9420 4365 46 8795 4145 47 85 10450 5875 56 9880 5665 57 9270 5445 59 8640 5230 61 75 11265 8715 77 10610 8410 79 9875 8070 82 9000 7675 85 61...

Page 11: ...55 3480 36 9135 3260 36 73 80 10785 4990 46 10220 4780 47 9620 4565 47 8995 4345 48 85 10650 6075 57 10080 5865 58 9470 5645 60 8840 5430 61 75 11365 8815 78 10710 8510 79 9975 8170 82 9100 7775 85 61...

Page 12: ...0 34 73 80 10480 4705 45 9920 4495 45 9315 4275 46 8690 4050 47 85 10345 5730 55 9775 5520 56 9165 5300 58 8535 5075 59 75 11165 8615 77 10510 8310 79 9775 7970 82 8900 7575 85 61 80 11120 10110 91 10...

Page 13: ...0 3445 36 9035 3220 36 73 80 10680 4905 46 10120 4695 46 9515 4475 47 8890 4250 48 85 10545 5930 56 9975 5720 57 9365 5500 59 8735 5275 60 75 11365 8815 78 10710 8510 79 9975 8170 82 9100 7775 85 61 8...

Page 14: ...4991 1 88 1 89 0 66 16596 15061 14068 12584 19212 16006 16165 13519 20173 17689 16999 15158 2 00 2 10 0 76 16751 15195 14199 12696 19268 16142 16212 13635 20387 17846 17179 15293 2 13 2 32 0 85 16884...

Page 15: ...its without electric heaters is 15 amps Overcurrent protection on 265 volt models must be cartridge style time delay fuses included and factory installed on Trane chassis 4 Total watts for 7 000 and 9...

Page 16: ...bottom of sleeve Bottom drain to be located by customer Drain kit shipped separate 4 Unit provides 20 percent outside air 5 Detachable cord ships attached to unit Cord can be removed for direct attac...

Page 17: ...17 PTAC PRC001 EN Dimension and Weights Field Supplied Extension...

Page 18: ...finished interior wall Notes 1 This kit completely encloses all plumbing and coils but still allows easy access to controls 2 The chassis can slide out for easy service without removing hydronic plum...

Page 19: ...ct extension kit are possible options These kits transfer air from one room to another yet allow different air flows for the rooms airflow distribution can be adjusted from 65 45 to 80 20 FrontView Du...

Page 20: ...ring installation Coils Coils will have rifled copper tubing expanded into rippled edge louvered aluminum fins Heat Pumps Heat pumps will include a changeover thermostat that senses an outside coil sw...

Page 21: ...ingTerminals The LS IN terminals will provide a connection for a switch that can be added to close the circuit and lockout the compressor and electric heat when the power company or energy management...

Page 22: ...be attached to the transition piece to carry up to 40 percent of the conditioned air to the adjoining room Powered OutsideVent and Damper Kit An optional power vent kit can be installed to increase cf...

Page 23: ...urity Key Locks The installation of Trane s security key locks helps prevent tampering of the controls used to set temperature heating and cooling functions Locks are available for all PTAC models Rem...

Page 24: ...ssor or connecting tubing which proves to be defective due to workmanship or materials Limited Second through FifthYear Warranty During the 2nd through 5th year Trane will provide free of charge funct...

Page 25: ...formation contact your local distributor dealer local district office or e mail us at comfort trane com SinceTheTrane Company has a policy of continuous product and product data improvement it reserve...

Reviews: