18-GE20D1-1E-EN
15
Modular Blower in Horizontal Right with “A” Coil
1.
Bend modular blower flanges down.
2.
Support the modular blower and coil independently.
3.
Match the coil up flush to the back of the modular blower.
4.
Seal per local codes and requirements.
Note:
Flat or dedicated horizontal coils may require flanges to be bent
upward.
Downflow Modular Blower with Coil
1.
Bend modular blower flanges down.
2.
Set the modular blower on top of the coil so that it is flush with the
back of the modular blower.
3.
Seal per local codes and requirements.