SPECIFICATIONS
Compressor Shutdown Protection (Auto Reset):
Stops Compressor
148 C (298 F)
Allows Compressor Start
90 C (194 F)
Bulb Mode:
Evaporator Fan Speed Settings
Flow High:
High speed only
Flow Low:
Low speed only
Flow Cycle:
Fans will cycle between low and high speed every 60 minutes
Defrost Termination Temperature Setting
4 to 30 C (40 to 86 F)
PHYSICAL SPECIFICATIONS
Fresh Air Exchange Venting System (Adjustable):
0 to 225 m
3
/hr (0 to 168 ft
3
/min.) @ 60 Hz
0 to 185 m
3
/hr (0 to 139 ft
3
/min.) @ 50 Hz
Evaporator Fan Blade Specifications:
:
Diameter
355 mm (14.0 in.)
Pitch
25°
Number of Fans
2
Weight (net):
Base Unit
380 Kg (875 lb.)
Water-cooled Condenser-Receiver Option
13.6 Kg (30 lb.)