Sample Model No.: S X H G - D 1 1 4 0 A H 7 C G 8 D 1 0 0 1 AT,etc
Digit No.: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21+
Digit 1 - Unit Type
Digit 12 - Exhaust Air Fan Drive
Digit 18 - Accessory Panel
S = Self-Contained
0 = None
0 = None
5 = 500 RPM
A = BAYSENS008*
Digit 2 - Unit Function(s)
6 = 600 RPM
B = BAYSENS010*
E = DX Cooling, Electric Heat
7 = 700 RPM
C = BAYSENS013*
F = DX Cooling, Natural G as Heat
8 = 800 RPM
D = BAYSENS014*
L = DX Cooling, Hot Water Heat
E = BAYSENS019*
S = DX Cooling, Steam Heat
Digit 13 - Filter
F = BAYSENS020*
X = DX Cooling, Extended Casings
A = Throwaway
G = BAYSENS021*
C = High-Efficiency Throwaway
Digit 3 - Unit Airflow
D = Bag with Prefilter
Digit 19 - Ambient Control
H = Single-Zone
E = Cartridge with Prefilter
0 = Standard
F = Throwaway Filter Rack Less Filter
Digit 4 - Development Sequence
Media
Digit 20 - Agency Approval
G
= Seventh G = Bag Filter Rack Less Filter Media 0 = None (UL G as Heater See Note 1)
1 = UL
Digits 5, 6, 7 - Nominal Capacity
Digit 14 - Supply Air Fan HP
2 = CSA
C90 = 90 Tons
C = 30 HP (2-15 HP)
Note: Includes UL classified gas
D11 = 105 Tons
D = 40 HP (2-20 HP)
heating section only w hen second
D12 = 115 Tons
E = 50 HP (2-25 HP)
digit of Model No. is a "F".
D13 = 130 Tons
F = 60 HP (2-30 HP)
G = 80 HP (2-40 HP)
Digits 21 - 36 - Miscellaneous
Digit 8 Pow er Supply
21 A = Unit Disconnect Switch
4 = 460/60/3 XL
Digit 15 - Supply Air Fan Drive
22 B = Hot G as Bypass
5 = 575/60/3 XL
A = 1000 RPM
23 C = Economizer Control
E = 200/60/3 XL
B = 1100 RPM
with Comparative Enthalpy
F = 230/60/3 XL
C = 1200 RPM
23 Z = Economizer Control
D = 1300 RPM
with Reference Enthalpy
Digit 9 - Heating Capacity
E = 1400 RPM
23 W = Economizer Control w/Dry Bulb
0 = No Heat
F = 1500 RPM
23 0 = None W/O Economizer
H = High Heat - 2 Stage
G = 1600 RPM
24 E = Low-Leak Fresh Air Dampers
J = Limited Modulating High Heat
25 F = High Duct Temperature Thermostat
P = Full Modulating High Heat
26 G = High Capacity Evaporator
Note: When the second digit calls
Digit 16 - Fresh Air
Coil (90 - 105 Only)
for "E" (electric heat), the follow ing
D = 0-100% Economizer (Std.)
27 K = G eneric BAS Module
values apply in the ninth digit:
28 L = High Efficiency Motors
W=190 kw
Digit 17 - System Control
(Supply and Exhaust)
Note: When the second digit calls for
1 = Constand Volume Control
29 M = Remote Human Interface
"L" or "S", one of the following valve
2 = VAV Supply Air Temperature
30 N = Ventilation O verride Module
size values must be in Digit 9:
Control without Inlet G uide Vanes
31 R = Extended Grease Lines
High Heat Coil: 3 = 1.0", 4 = 1.25",
3 = VAV - Supply Air Temperature
32 T = Access Doors
5 = 1.50", 6 = 2.0", 7 = 2.5"
Control with Inlet Guide Vanes
33 V = Inter-processor Communication
Low Heat Coil: C = 1.0", D = 1.25",
4 = Space Pressure Control with
Bridge
E = 1.50", F = 2.0", G = 2.5"
Exhaust VFD w/o Bypass
34 0 = No communication module
5 = Space Pressure Control with
34 Y = Trane Communication Interface Module
Digit 10 - Design Sequence
Exhaust and Bypass
34 7 = LonTalk® Communication Interface Module
W = Disconnect Redesign
6 = VAV Supply Air Temperature Control
35 0 = None
Note: Sequence may be any letter
with VFD without Bypass
36 6 = Factory-Powered 15A G FI
A thru Z, or any digit 1 thru 9.
7 = VAV Supply Air Temperature Control
Convenience O utlet
with VFD and Bypass
8 = Supply and Exhaust Fan with
Digit 11 - Exhaust O ption
VFD and without Bypass
O = None
9 = Supply and Exhaust Fan with
7 = 100%, 15 HP w/ Statitrac
VFD and Bypass
8 = 100%, 20 HP w/ Statitrac
9 = 100%, 25 HP w/ Statitrac
F = 50%, 15 HP
H = 100%, 30 HP w/ Statitrac
J = 100%, 40 HP w/ Statitrac
K = 100%, 15 HP w/o Statitrac (CV O nly)
L = 100%, 20 HP w/o Statitrac (CV O nly)
M = 100%, 25 HP w/o Statitrac (CV O nly)
N = 100%, 30 HP w/o Statitrac (CV O nly)
P = 100%, 40 HP w/o Statitrac (CV O nly)
Echelon, LON, LONWORKS, LonBuilder, NodeBuilder, LonManager,
LonTalk, LonUsers, Neuron, 3120, 3150, the Echelon logo, and the
LonUsers logo are trademarks of Echelon Corporation registered in the
United States and other countries. LonLink, LonResponse, LonSupport,
LonMaker, and LonPoint are trademarks of Echelon Corporation.
Summary of Contents for INTELLIPAK RT-SVX10C-EN
Page 16: ...15 Figure 3 1 Minimum Operation and Service Clearances for Single Multiple Unit Installation...
Page 17: ...16 Figure 3 2A SAHF Cooling Only Units 20 thru 75 Ton...
Page 19: ...18 Figure 3 2B SEHF SFHF SLHF SSHF SXHF Units 20 thru 75 Ton...
Page 21: ...20 Figure 3 2C S_HG Cooling Heating Units 90 through 130 Ton...
Page 25: ...24 Figure 3 4 Typical Unit Rigging Figure 3 5 Unit Base Roof Curb Section...
Page 52: ...51 Field Connection Diagram Notes for 20 through 130 Ton CV or VAV Applications...
Page 86: ...84 Figure 4 6 Compressor Locations...
Page 117: ...115...
Page 118: ...116...