RT-SVX056D-GB
14
IC 038
IH 038
IC 048
IH 048
IC 058
IC 063
Cooling Mode
Net Cooling Capacity (1)
kW
41
40
50
50
61
69
Total Power Input (1)
kW
14.0
13.41
16.6
17.6
20.7
25.1
Electric Heater
Number of capacity step
Nb
2
2
2
2
2
2
Capacity Steps (1)
kW
12,5 / 12,5
12,5 / 12,5
12,5 / 12,5
12,5 / 12,5
12,5 / 25
12,5 / 25
Electrical Data (2) (3)
Main Power Supply
V/Ph/Hz
400 / 3 /50
400 / 3 /50
400 / 3 /50
400 / 3 /50
400 / 3 /50
400 / 3 /50
Unit Max Amps
A
37
37
45
45
54
63
Unit Start Up Amps (without soft starter)
A
124
124
156
156
173
185
Unit Start Up Amps (with soft starter)
A
88
88
111
111
125
134
Maximum Short Circuit rating for 0.3 sec
kA
15
15
15
15
15
15
Disconnect switch std unit
Sirco 125A
Max power cable cross section (Standard unit)
mm2
50
Disconnect switch unit with option (heat recovery, Exhaust
fan, Return Fan, Auxiliary heat)
Sirco 250A
Max power cable cross section (unit with option-Heat
recovery, Exhaust fan, Return fan, Auxiliary heat)
mm2
150
Electric Heater
A
36.1
36.1
36.1
36.1
36.1
36.1
Outdoor fan: Low Ambient
A
0.8
0.8
1.6
0.8
1.6
1.6
Indoor fan: Oversized
A
0.0
0.0
0.0
0.0
0.0
0.0
Exhaust Fan (AC)
A
0.6
0.6
0.6
0.6
0.6
0.6
Exhaust Fan (EC)
A
5
5
5
5
5
5
Return Roofcurb
A
5.3
5.3
5.3
5.3
5.3
5.3
Heat Recovery (not included current for oversized fan)
A
7.5
7.5
7.5
7.5
7.5
7.5
Gas burner (staged)
A
0.4
0.4
0.4
0.4
0.4
0.4
Gas burner (modulating)
A
0.3
0.3
0.3
0.3
0.3
0.3
Frame
Frame
Frame 1
Frame 1
Frame 1
Frame 1
Compressor
Number of Circuits
#
1
1
1
1
1
1
Number of Compressor per Circuits
#
2
2
2
2
2
2
Type
Scroll
Scroll
Scroll
Scroll
Scroll
Scroll
Model
ZP83KCE TFD 422 ZP83KCE TFD 422 ZP104KCE TFD455 ZP83KCE TFD 422 ZP122KCE TFD 455
ZP143KCE TFD
455
Max Amps per Compressor
A
14.3
14.3
17.1
17.1
20.1
24.5
Locked Rotor Amps per Compressor
A
101
101
128
128
139
146
Oil & Refrigerant
Oil quantity per compressors OIL58E/OIL57E (6)
l
1.8
1.8
2.5
2.5
2.5
2.5
Oil quantity OIL58E/OIL57E (6)
l
3.5/3.5
3.6
5.0/5.0
5.0
5.0/5.0
5.0/5.0
Refrigerant charge per circuit
kg
4.33
4.33
7.44
7.44
7.20
7.70
Outdoor Coil
Type
MCHE
Fins & Tubes
MCHE
Fins & Tubes
MCHE
MCHE
Tube Size
Inches
5/16”
5/16”
Face Area
m2
2.92
2.05
2.92
2.92
2.92
2.92
Rows/Fin Series
#/FPF
3 / 192
3 / 192
Number of Tubes in the height
128 (96-32)
48
128 (96-32)
48
128 (96-32)
128 (96-32)
Indoor Coil
Type
Fins & Tubes
Fins & Tubes
Fins & Tubes
Fins & Tubes
Fins & Tubes
Fins & Tubes
Tube Size
Inches
3/8"
3/8”
3/8"
3/8”
3/8"
3/8"
Face Area
m2
1.812
1.812
1.812
1.812
1.812
1.812
Rows/Fin Series
#/FPF
3 / 168
3 / 168
3 / 168
3 / 168
3 / 168
3 / 168
Number of Tubes in the height
48
48
48
48
48
48
Drain Connection No./Size
mm
35
35
35
35
35
35
Hot Water Coil
Type
Fins & Tubes
Fins & Tubes
Fins & Tubes
Fins & Tubes
Fins & Tubes
Fins & Tubes
Tube Size
Inches
3/8"
3/8”
3/8"
3/8”
3/8"
3/8"
Face Area
m2
0.769
0.769
0.769
0.769
0.769
0.769
Rows/Fin Series
#/FPF
2 / 144
2 / 144
2 / 144
2 / 144
2 / 144
2 / 144
Number of Tubes in the height
25
25
25
25
25
25
Indoor Fan
Standard
Type
Plug Fans
Plug Fans
Plug Fans
Plug Fans
Plug Fans
Plug Fans
Model
K3G500PA2371
K3G500PA2371
K3G500PA2371
K3G500PA2371
K3G500PB3301
K3G500PB3301
Minimum Airflow
m3/h
6240
6240
7200
7200
8880
10300
Nominal Airflow
m3/h
7800
7800
9000
9000
11100
12400
Maximal Airflow
m3/h
10140
10140
11700
11700
14430
16120
Number
#
1
1
1
1
1
1
Diameter
mm
500
500
500
500
500
500
Drive Type
EC Motors
EC Motors
EC Motors
EC Motors
EC Motors
EC Motors
Motor Power (Eurovent condition)
kW
0.93
0.93
1.15
1.15
1.91
2.59
Motor Max Amps per fan
A
5.3
5.3
5.3
5.3
9
9
IC - IH General Data
Table 3
–
Single circuit