![Trane CleanEffects Air Filtration System User'S Information Manual Download Page 7](http://html1.mh-extra.com/html/trane/cleaneffects-air-filtration-system/cleaneffects-air-filtration-system_users-information-manual_1148952007.webp)
32-5038-06
Numbers in [brackets] are for 50 Hz international systems.
7
User’s Information
SET-UP MODE
You can customize the operation of the air cleaner to
meet the needs of your home and family using the SET-
UP mode.
To enter the SET-UP mode, press and hold BOTH the
POWER and the RESET buttons for a minimum of 5 [6]
seconds. The LED display will light up indicating the
current settings. If the settings were not changed during
installation into your home, the LED's will light up with
the factory settings as shown in Figure 19.
2. After washing, drain as much water as possible from
the COLLECTION CELLS.
3. Holding the sides of the COLLECTION CELLS,
gently tap the cells on a flat surface to dislodge any
water droplets inside the COLLECTION CELLS. After
tapping, wipe down the surfaces of the COLLEC-
TION CELLS to remove any visible droplets of water.
Fig. 17
4. When there are no visible water droplets left in the
COLLECTION CELLS, reinstall them into the air
cleaner cabinet. Be sure to fold the COLLECTION
CELL handles flat.
Tap
Gently
Handles Fold
Flat
Fig. 18
Fig. 19
You may select the cleaning intervals of the PRE-
FILTER and the COLLECTION CELLS as well as the
power setting of the FIELD CHARGER by cycling
through the various settings. Once you have made the
desired changes, press and hold BOTH the POWER and
the filter RESET buttons for a minimum of 5 [6] seconds
to exit the SET-UP mode.
PRE-FILTER Timer Setting
The GREEN LED lights are used to set the PRE-FILTER
cleaning interval for one, two, or three months [5, 10, or
15 weeks]. The number of illuminated GREEN LED
lights indicates the current setting. The factory setting
is 2 months [10 weeks] of run time (see Figure 19).
COLLECTION CELL Timer Setting
The YELLOW LED lights are used to set the COLLEC-
TION CELLS cleaning interval for two, four, six, or nine
months [10, 20, 31, or 46 weeks]. The number of
illuminated YELLOW LED lights indicates the current
setting as shown in Figure 19. The factory setting is 6
months [31 weeks] of run time.
FIELD CHARGER Power Level Setting
The RED LED lights are used to set the power level of
the FIELD CHARGER for maximum, medium, or mini-
mum. The number of illuminated RED LED lights
indicates the current setting as shown in Figure 22. The
factory setting is for maximum.
Lower settings will reduce the slight sound emitted by
the unit with minimal loss of air cleaning efficiency, if
desired.
Lower settings will also further reduce the very low
ozone produced by the air cleaner. The U.S. Food and
Drug Administration recommends indoor ozone concen-
trations should not exceed 50 parts per billion. Your air
cleaner will contribute only 5 parts per billion at the
factory setting and can be reduced to 3 parts per billion
at the minimum setting.
G1
G2
G3
Y1
Y3
Y4
R1
R2
R3
Y2
CLEAN
DIRTY
Power Level
Collection Cell
Pre-Filter
Factory settings
FIELD CHARGER Power
Maximum
COLLECTION CELL
6 Months [31 weeks]
PRE-FILTER
2 Months [10 weeks]
RESET TIMERS
To reset the PRE-FILTER timer, press and hold the
RESET button until the PRE-FILTER LED turns off. (1 to
2 seconds)
To reset the Collection Cell timer, press and hold the
RESET button until the COLLECTION CELL LED’s turn
off. (4 to 5 seconds)