Trane BAYWACC11SC1AA Installer'S Manual Download Page 5

Page 5

INSTALLER'S GUIDE

Hot

 W

ate

r

Out

Hot

 W

ate

r

In

C

US

ELE

CTR

ICA

L S

AFE

TY

NRT

L L

IST

ED

MET

UL

 1995

CAN/CSA-

C22

.2 No

. 23

6

E21

236

5

STEP 2

 - Place hydronic coil on top of the air handler 

cabinet.  

1.    Flip coil over so the gasket is on the bottom and the 

supply side flanges are facing up.  

2.    Set the coil on top of the air handler.
3.    Align the coil with the air handler case. 

Section 4. Install Hydronic Coil

STEP 1

 - Place the hydronic coil with the supply side 

facing down.  Apply gasket material onto the coil 

flanges.  On the front flange, the gasket material must 

be at the inner edge to create an airtight seal.

Gasket

Place gasket material 

on the inner edge of 

front side flange

Hot W

ater

Out

Hot W

ater

In

C

US

ELECT

RICAL

 SAFET

Y

NRT

L LIST

ED

MET

UL 1995

CAN/C

SA-

C22.2 N

o. 23

6

E212365

Hot W

ater

Out

Hot W

ater

In

C

US

ELECT

RICAL

 SAFET

Y

NRTL LI

STED

MET

UL 1995

CAN/CSA-C22.2 No. 23

6

E212365

STEP 3

 - Wrap the coil attachment flange around the 

air handler and coil.  It should have equal amounts of 

material covering the coil and air handler cabinet.

1.    Take the attachment flange and wrap it around the air 

handler and coil.

2.    Equal amounts of material should cover the coil and air 

handler.

Supply Side

Supply Side

Summary of Contents for BAYWACC11SC1AA

Page 1: ...s installation must comply with NATIONAL STATE AND LOCAL CODES 18 GJ37D1 6A EN Model BAYWACC11SC1AA Table of Contents Section 1 Safety Considerations 2 Section 2 General Information 3 Section 3 Hydron...

Page 2: ...ITS USE s s WARNING ELECTRICAL HAZARD DISCONNECT ALL ELECTRICAL POWER INCLUDING REMOTE DISCONNECTS BEFORE INSTALLING OR SERVICING FOLLOW PROPER LOCKOUT TAGOUT PROCEDURES TO ENSURE THE POWER CAN NOT BE...

Page 3: ...m one of the side conduit entry points Section 2 General Information Water Coil Model Number Nomenclature Digit 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Coil number B A Y W A C C 1 1 S C 1 A A A Brand B Bo...

Page 4: ...SAFET Y NR TL LIS TED MET UL 1995 CAN CSA C22 2 No 236 E212365 Section 3 Hydronic Coil Assembly Field Pipe Connections 7 8 OD 3 4 ID copper tubing Hydronic Coil 12 Field Provided Screws 1 2 long Coil...

Page 5: ...flanges On the front flange the gasket material must be at the inner edge to create an airtight seal Gasket Place gasket material on the inner edge of front side flange Hot Wat er Out Hot Wat er In C...

Page 6: ...g directions Section 5 Piping NOTE The hydronic coil can be installed in upflow downflow or horizontal positions When the air han dler is installed in the horizontal orientation an addi tional strap m...

Page 7: ...110 60251 127 9 28861 97 47528 113 66048 130 3 24485 91 41011 101 56072 116 6 29226 94 48327 108 64905 123 9 31291 95 51432 111 71149 126 3 26736 89 44387 98 60848 112 6 31913 92 52305 105 70434 119 9...

Page 8: ...Example 4T outdoor unit x 400 HP Heating cfm ton 1600 Section 8b Communicating Operation AIRFLOW DEMAND IN COMMUNICATING MODE COIL MODEL AHU MODEL MAXIMUM CFM SERIAL COMMUNICATING BAYWAAA05SC1A w TAM9...

Reviews: