14
Heating Airflow, horizontal or downflow from .2 to .6” wg.
Selection
Low Stage High Stage
7-OFF
8-OFF
A
600
850
7-ON
8-OFF
B
625
900
7-OFF
8-ON
C
650
925
7-ON
8-ON
D
700
975
4YCY4024A1064
Switch Settings
Nominal Airflow
Selection
Low Stage High Stage
7-OFF
8-OFF
A
725
1000
7-ON
8-OFF
B
775
1075
7-OFF
8-ON
C
850
1150
7-ON
8-ON
D
925
1250
4YCY4030A
Switch Settings
Nominal Airflow
Selection
Low Stage High Stage
7-OFF
8-OFF
A
725
1000
7-ON
8-OFF
B
775
1075
7-OFF
8-ON
C
850
1150
7-ON
8-ON
D
925
1250
Selection
Low Stage High Stage
7-OFF
8-OFF
A
825
1100
7-ON
8-OFF
B
875
1175
7-OFF
8-ON
C
950
1275
7-ON
8-ON
D
1025
1375
* can be 1 or 3
4YCY4036A*075
4YCY4036A*096
Switch Settings
Nominal Airflow
Switch Settings
Nominal Airflow
* can be 1 or 3
Selection
Low Stage High Stage
7-OFF
8-OFF
A
1075
1375
7-ON
8-OFF
B
1100
1450
7-OFF
8-ON
C
1150
1500
7-ON
8-ON
D
1200
1575
4YCY4042A
Switch Settings
Nominal Airflow
Selection
Low Stage High Stage
7-OFF
8-OFF
A
1075
1375
7-ON
8-OFF
B
1100
1450
7-OFF
8-ON
C
1150
1500
7-ON
8-ON
D
1200
1575
Selection
Low Stage High Stage
7-OFF
8-OFF
A
1050
1500
7-ON
8-OFF
B
1100
1575
7-OFF
8-ON
C
1150
1625
7-ON
8-ON
D
1200
1700
4YCY4048A*096
4YCY4048A*120
Nominal Airflow
* can be 1 or 3
* can be 1 or 3
Switch Settings
Switch Settings
Nominal Airflow
Low Stage High Stage
7-OFF
8-OFF
A
1375
1800
7-ON
8-OFF
B
1450
1900
7-OFF
8-ON
C
1525
1975
7-ON
8-ON
D
1575
2075
Switch Settings
Selection
4YCY4060A
Nominal Airflow
Indoor Blower Performance
Summary of Contents for 4YCY4024A
Page 16: ...16 Typical Wiring ...
Page 17: ...17 From Dwg 21D757165 P02 Typical Wiring ...
Page 23: ...23 Dimensional Data 4YCY4024A through 4YCY4036A 1 of 3 ...
Page 24: ...24 Dimensional Data 4YCY4024A through 4YCY4036A 2 of 3 ...
Page 25: ...25 4YCY4024A through 4YCY4036A 3 of 3 Dimensional Data ...
Page 26: ...26 Dimensional Data 4YCY4042A through 4YCY4060A 1 of 3 ...
Page 27: ...27 Dimensional Data 4YCY4042A through 4YCY4060A 2 of 3 ...
Page 28: ...28 4YCY4042A through 4YCY4060A 3 of 3 Dimensional Data ...