84
TK 61738-2-OP-EN
8. Connect the black negative (–) jumper cable to the negative (–) battery
terminal on a good battery. Do not let the other end of the jumper cable
touch anything that conducts electricity.
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss V
Vo
olltta
ag
ge
e!!
DO NOT connect to the positive connection on the starter motor, which
is located on the top right of the starter motor.
9. Connect the black negative (–) jumper cable to the lower starter
mounting bolt on the unit’s engine.
10. If you are using a vehicle to jump start the unit, start the vehicle and let it
run for a few minutes. This will help charge the discharged battery.
D
DA
AN
NG
GE
ER
R
R
Riisskk o
off IIn
njju
urry
y!!
Keep your hands, clothing, and tools clear of fans and/or belts when
working on a unit that is running or when opening or closing compressor
service valves. Loose clothing might entangle moving pulleys or belts,
causing serious injury or possible death.
11. Turn the unit on and let it start automatically or start it manually. If the
unit will not crank or start, contact a qualified technician.
N
No
otte
e:: Some units with microprocessors will show an alarm code and will
not try to start the unit until battery voltage is above 10 volts.
12. After the unit starts, remove the jumper cables in reverse order: black
negative (–) from the unit starter mounting bolt, black negative (–) from
the good battery, red positive (+) from the good battery, and red positive
(+) from the unit battery (that was discharged).