background image

©2020 Trane

PTAC-SVN028E-EN

Introduction

Read this manual thoroughly before operating or servicing this unit.

Warnings, Cautions, and Notices

Safety advisories appear throughout this manual as required. Your personal safety and the
proper operation of this machine depend upon the strict observance of these precautions.

The three types of advisories are defined as follows:

WARNING

Indicates a potentially hazardous situation which, if not avoided, could result in
death or serious injury.

CAUTION

Indicates a potentially hazardous situation which, if not avoided, could result in
minor or moderate injury. It could also be used to alert against unsafe practices.

NOTICE

Indicates a situation that could result in equipment or property-damage only
accidents.

Important Environmental Concerns

Scientific research has shown that certain man-made chemicals can affect the earth’s naturally
occurring stratospheric ozone layer when released to the atmosphere. In particular, several of the
identified chemicals that may affect the ozone layer are refrigerants that contain Chlorine,
Fluorine and Carbon (CFCs) and those containing Hydrogen, Chlorine, Fluorine and Carbon
(HCFCs). Not all refrigerants containing these compounds have the same potential impact to the
environment. Trane advocates the responsible handling of all refrigerants-including industry
replacements for CFCs and HCFCs such as saturated or unsaturated HFCs and HCFCs.

Important Responsible Refrigerant Practices

Trane believes that responsible refrigerant practices are important to the environment, our
customers, and the air conditioning industry. All technicians who handle refrigerants must be
certified according to local rules. For the USA, the Federal Clean Air Act (Section 608) sets forth
the requirements for handling, reclaiming, recovering and recycling of certain refrigerants and
the equipment that is used in these service procedures. In addition, some states or municipalities
may have additional requirements that must also be adhered to for responsible management of
refrigerants. Know the applicable laws and follow them.

W

WA

AR

RN

NIIN

NG

G

P

Prro

op

pe

err F

Fiie

elld

d W

Wiirriin

ng

g a

an

nd

d G

Grro

ou

un

nd

diin

ng

g R

Re

eq

qu

uiirre

ed

d!!

F

Fa

aiillu

urre

e tto

o ffo

ollllo

ow

w cco

od

de

e cco

ou

ulld

d rre

essu

ulltt iin

n d

de

ea

atth

h o

orr sse

erriio

ou

uss iin

njju

urry

y..

A

Allll ffiie

elld

d w

wiirriin

ng

g M

MU

US

ST

T b

be

e p

pe

errffo

orrm

me

ed

d b

by

y q

qu

ua

alliiffiie

ed

d p

pe

errsso

on

nn

ne

ell.. IIm

mp

prro

op

pe

errlly

y iin

nsstta

alllle

ed

d a

an

nd

d

g

grro

ou

un

nd

de

ed

d ffiie

elld

d w

wiirriin

ng

g p

po

osse

ess F

FIIR

RE

E a

an

nd

d E

EL

LE

EC

CT

TR

RO

OC

CU

UT

TIIO

ON

N h

ha

azza

arrd

dss.. T

To

o a

av

vo

oiid

d tth

he

esse

e h

ha

azza

arrd

dss,,

y

yo

ou

u M

MU

US

ST

T ffo

ollllo

ow

w rre

eq

qu

uiirre

em

me

en

nttss ffo

orr ffiie

elld

d w

wiirriin

ng

g iin

nsstta

alllla

attiio

on

n a

an

nd

d g

grro

ou

un

nd

diin

ng

g a

ass d

de

essccrriib

be

ed

d iin

n

N

NE

EC

C a

an

nd

d y

yo

ou

urr llo

occa

all//sstta

atte

e//n

na

attiio

on

na

all e

elle

eccttrriicca

all cco

od

de

ess..

Summary of Contents for ProSpace SLV0035

Page 1: ...ning Improperly installed adjusted or altered equipment by an unqualified person could result in death or serious injury When working on the equipment observe all precautions in the literature and on the tags stickers and labels that are attached to the equipment April 2020 P PT TA AC C S SV VN N0 02 28 8E E E EN N Installation Guide ProSpace Packaged Terminal Air Conditioner PTAC Wall Sleeve Part...

Page 2: ...ractices are important to the environment our customers and the air conditioning industry All technicians who handle refrigerants must be certified according to local rules For the USA the Federal Clean Air Act Section 608 sets forth the requirements for handling reclaiming recovering and recycling of certain refrigerants and the equipment that is used in these service procedures In addition some ...

Page 3: ...iz ze ed d e el le ec ct tr ri ic ca al l c co on nt ta ac ct t a ar rc c o or r f fl la as sh h t te ec ch hn ni ic ci ia an ns s M MU US ST T p pu ut t o on n a al ll l P PP PE E i in n a ac cc co or rd da an nc ce e w wi it th h O OS SH HA A N NF FP PA A 7 70 0E E o or r o ot th he er r c co ou un nt tr ry y s sp pe ec ci if fi ic c r re eq qu ui ir re em me en nt ts s f fo or r a ar rc c f fl ...

Page 4: ...ion 7 Preparing the Wall 7 Preparing the Case 8 Installation 9 Installing the Wall Sleeve in Wall Opening 9 Installing Foam Gasket on Extended Wall Sleeve As Required for Standard Vertical Louvered Grilles 10 Weatherproofing 10 Installing in Extra Thick Walls 11 Electrical Requirements for 208 230V and 265V 12 Wall Sleeve Drain Kit 12 Table of Contents ...

Page 5: ...ide wall to ensure proper distribution of conditioned air Locate it in a portion of the wall where there is no electrical wiring plumbing or obstructions immediately inside or outside N No ot te e The unit generates condensate in some weather conditions so consideration for management of that water may be important Wall Sleeve Dimensions Dimensions A B Allow for wall finishing Allow for floor fini...

Page 6: ... ot te e Care should be taken in the location of the electrical entry in relationship to the wall sleeve to ensure access to power once the unit is installed L Lo oc ca at ti io on n D Di im me en ns si io on ns s a an nd d L Le ev ve el li in ng g ...

Page 7: ...h fits approximately 3 stud spaces For existing construction wall openings must be made Wall openings of the proper dimensions are essential to avoid the necessity of fillers or additional framing B N No ot te e Use lintel to support brick or other materials above the air conditioner case Lintel is not necessary if this is under a windowsill N No ot te es s Additional depths are 16 18 20 and 24 He...

Page 8: ...p and sides of the wall sleeve at the desired location front to rear with angles facing toward rear outside 2 Position the case angles vertically on each side of the wall sleeve to provide a level installation 3 Mark the wall sleeve through the holes in the case angles 4 Drill 5 32 diameter holes at marked locations on the wall sleeve 5 Assemble the angles using only 10x1 2 screws Install the scre...

Page 9: ...under the case and caulking applied between the drip rail and case I Im mp po or rt ta an nt t Install the wall sleeve level from side to side horizontally and tilted 1 4 bubble outward and downward N Ne ev ve er r t ti il lt t t th he e w wa al ll l s sl le ee ev ve e i in nw wa ar rd d 2 Firmly secure the wall sleeve to the wall structure N No ot te e Do not drill any holes in the bottom of the ...

Page 10: ...trip on each support as shown below Foam Gasket 2 Places Optional Grille Attached On This Surface 3 Attach the optional grille to the enclosure Refer to the ProSpace PTAC Grille Installation Instructions PTAC SVN027 Weatherproofing Use caulk or equivalent materials to weatherproof any gaps between the exterior and interior walls and the case N No ot te e It is critical to caulk around the perimete...

Page 11: ...ll p 7 If the wall sleeve is being installed in a wall where the recess is 3 or less and an extended wall case is not used flashing must be installed under the wall sleeve and extend up to 2 inches on each side The flashing must include a drip rail as shown below N No ot te e It is critical to caulk around the perimeter of the wall sleeve on all four sides where it joins the building to prevent ai...

Page 12: ...end to a wall receptacle located within the area shown below N No ot te e The rear protective panel must remain in place until ready to install the chassis N No ot te e Aluminum wiring in the structure may pose special problems and it is recommended to consult with a qualified electrician Wall Sleeve Drain Kit If it is necessary to install a drain kit use KIT17867 Internal External Drain With an e...

Page 13: ...PTAC SVN028E EN 13 N No ot te es s ...

Page 14: ...14 PTAC SVN028E EN N No ot te es s ...

Page 15: ...PTAC SVN028E EN 15 N No ot te es s ...

Page 16: ...For more information please visit trane com or tranetechnologies com Trane has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice We are committed to using environmentally conscious print practices PTAC SVN028E EN 27 Apr 2020 Supersedes PTAC SVN028D EN April 2019 2020 Trane ...

Reviews: