Tightening 
torque
Gland body 
and lock nut 
(if applicable):

Gland size

Torque (Nm)

M50

50

M63

63

M75

75

M90

90

Tightening torque
Gland body 
and lock nut (if 
applicable):

Gland size

Torque (Nm)

M16

16

M20

20

M25

25

M32

32

M40

40

Tightening torque
Compression nut:

Sealing ring code Torque (Nm)

Clamping 
Range:

Sealing ring code Clamping Range

A1

3

A1

2,0-6,0 mm

B1

3

B1

5,0-9,1 mm

B2

6

B2

4,5-7,5 mm

C1

5

C1

9,0-14,3 mm

C2

5

C2

6,0-10,0 mm

C3

5

C3

8,5-13,0 mm

D1

8

D1

15,0-20,1 mm

D2

8

D2

11,0-15,0 mm

D3

10

D3

5 x 11 mm

D4

10

D4

5 x 13 mm

D5

10

D5

5 x 15 mm

D9

8

D9

13,0-17,0 mm

E1

15

E1

20,0-23,0 mm

E2

15

E2

18,0-20,1 mm

F1

15

F1

26,5-32,4 mm

F2

15

F2

23,0-29,0 mm

G1

40

G1

32,0-38,5 mm

G2

40

G2

29,0-35,0 mm

H1

40

H1

35,0-41,0 mm

I1

50

I1

40,0-44,5 mm

I2

40

I2

38,4-43,0 mm

J1

70

J1

44,0-50,5 mm

J2

40

J2

42,0-46,0 mm

K1

70

K1

50,0-56,5 mm

K2

50

K2

47,0-53,0 mm

L1

70

L1

55,0-59,0 mm

L2

70

L2

58,0-63,0 mm

L3

50

L3

53,0-58,0 mm

L4

50

L4

56,0-62,0 mm

M1

50

M1

62,0-68,0 mm

M2

50

M2

60,0-66,0 mm

N1

70

N1

68,0-72,0 mm

N2

70

N2

65,0-70,0 mm

O1

70

O1

72,0-78,0 mm

O2

70

O2

78,0-83,0 mm

O3

70

O3

69,0-75,0 mm

O4

70

O4

75,0-81,0 mm

TEF E204 - 622/E205 - 624 Ex e

   

CABLE GLAND USER MANUAL

Summary of Contents for TEF E204-622 Ex e

Page 1: ...51 57 89 50 Office Oslo Luhrtoppen 2 N 1470 Lørenskog Norway T 47 24 08 44 10 IMPORTANT Read this instruction carefully before installing the product E204 622 E205 624 CABLE GLANDS TEF E204 622 Ex e CABLE GLAND TEF E205 624 Ex e CABLE GLAND ZONE 1 ZONE 2 SAFE AREA USER MANUAL Subject to change without prior notice TUM4302 REV F 22 10 2019 ...

Page 2: ...If the chamfer is too small the insertion of the gland may be difficult or impossible and if the chamfer is too big the O ring seal may not seal properly with the enclosure wall It is the installer s responsibility to verify that the seal after installation is sufficient for both clearance holes and threaded holes TOOLS REQUIRED Wrench according to size of cable gland MAINTENANCE INSTRUCTIONS The ...

Page 3: ...g to list on the next page for correct tightening torque 2 Place the compression nut 1 over the cable 3 Place the washer 2 then sealing ring 3 over the cable 4 Carefully cut back the outer sheet of the cable as shown on drawing 5 Feed conductors through gland body 4 Conductors and outer sheath goes through the connector 4 and into the enclosure 6 Press the sealing ring 3 and Washer 2 into gland bo...

Page 4: ...4 5 7 5 mm C1 5 C1 9 0 14 3 mm C2 5 C2 6 0 10 0 mm C3 5 C3 8 5 13 0 mm D1 8 D1 15 0 20 1 mm D2 8 D2 11 0 15 0 mm D3 10 D3 5 x 11 mm D4 10 D4 5 x 13 mm D5 10 D5 5 x 15 mm D9 8 D9 13 0 17 0 mm E1 15 E1 20 0 23 0 mm E2 15 E2 18 0 20 1 mm F1 15 F1 26 5 32 4 mm F2 15 F2 23 0 29 0 mm G1 40 G1 32 0 38 5 mm G2 40 G2 29 0 35 0 mm H1 40 H1 35 0 41 0 mm I1 50 I1 40 0 44 5 mm I2 40 I2 38 4 43 0 mm J1 70 J1 44...