background image

R. Stahl Tranberg AS 

E

 

[email protected]

 | 

stahl-tranberg.com

Main office: Strandsvingen 6

 | 

N-4032 Stavanger

 | 

Norway 

| T

 

+47 51 57 89 00

 |

 

F

 +47 51 57 89 50

Office Oslo: Luhrtoppen 2

 | 

N-1470 Lørenskog

 

|

 Norway 

| T

 +47 24 08 44 10

TEF 9964

  

XENON HELIDECK FLOODLIGHT INDUSTRY USER MANUAL

TECHNICAL DATA

Material: 

Acid proof stainless steel. Polycarbonate front glass.

Input voltage: 

230/254 VAC  50/60Hz 
110/120 VAC  50/60Hz 
24 VDC  

Power consumption: 

50Watt

IP-rating without drain plug: 

IP 66/67 ( according to EN 60529) 

IP-rating with drain plug: 

IP 66 

Cable glands: 

2 X M25, E204/622 M25/D kit

 

Cable diam: 11,0-15,0 mm

                       

 

             15,0-20,1 mm               

Area of use: 

Safe area

Weight: 

10 kg.

SPARE PARTS

Part No.

Xenon Lamp, D2S. 35W, For TEF 9964

9400074

Front Glass

3241

High Voltage Igniter Unit Xenon

9400103

Locknut for Xenon D2S

9400108

Transformer W/ Mounting Bracket for 9964, 230/254 VAC

4386

Transformer W/ Mounting Bracket for 9964, 110 VAC

4387

Rectifier For 9964 Xenon Helideck Light

3069

Cable Gland Exe E204/622 M25/D kit 11,0-20,1 mm/9mm Brass

6222502

Complete Insert for TEF 9964 230/254V

3173

Complete Insert for TEF 9964 110V

3249

Complete Insert for TEF 9964 24V

4210

Tool for Replacing Xenon Lamp in TEF 9964 Helideck Floodlight

4676

Summary of Contents for TEF 9964 Helideck

Page 1: ...way T 47 51 57 89 00 F 47 51 57 89 50 Office Oslo Luhrtoppen 2 N 1470 Lørenskog Norway T 47 24 08 44 10 IMPORTANT Read this instruction carefully before installing the product LIGHTING TEF 9964 XENON HELIDECK FLOODLIGHT INDUSTRY SAFE AREA USER MANUAL Subject to change without prior notice TUM1024 REV L 26 01 2022 ...

Page 2: ...wdriver for open closing the cover of the junction box 3 mm flat screwdriver for installing the cable in the terminal block 5 5 mm flat screwdriver for removing the lamp insert 32 mm wrench to assembly the cable gland 30 mm wrench to tighten the lock nut and the pressure nut MAINTENANCE INSTRUCTIONS The luminaire should be inspected according to Company routines The manufacturer suggests regular c...

Page 3: ...unless stated otherwise 2 Secure the floodlight to the helideck by means of four M10 bolts 3 Open the enclosure cover on rear Replace cable gland gaskets as required to match the cable diameter Unused cable glands should always be replaced with a blind plug 4 Connect cables and replace the enclosure cover DIMENSIONS 5 Luminaire housing shall be connected to earth potential by groundwire of min cro...

Page 4: ...Loosen clamps and remove front ring Warning High voltage components inside lamp Make sure to disconnect power before opening Distance bracket Distance bracket Holding clip Old version 2 REMOVE HOLDING CLIP AND OR DISTANCE BRACKET 1 REMOVE FRONT RING 3 SLIDE OUT LAMP INSERT New version ...

Page 5: ...ng ring 4b 1 Disassemble the reflector unit 3 x M4 screws Disconnect the hight voltage plug 4b 2 Position lamp removal tool over locking ring as shown below Twist approx 30 degrees anti clockwise 4b 3 Remove xenon lamp Locking ring Xenon lamp 4A REMOVE LIGHT BULB NEW VERSION 4B REMOVE LIGHT BULB OLD VER Note make sure the new xenon bulb is clean Do not touch the glass part of the bulb Mount lamp b...

Page 6: ...IP rating with drain plug IP 66 Cable glands 2 X M25 E204 622 M25 D kit Cable diam 11 0 15 0 mm 15 0 20 1 mm Area of use Safe area Weight 10 kg SPARE PARTS Part No Xenon Lamp D2S 35W For TEF 9964 9400074 Front Glass 3241 High Voltage Igniter Unit Xenon 9400103 Locknut for Xenon D2S 9400108 Transformer W Mounting Bracket for 9964 230 254 VAC 4386 Transformer W Mounting Bracket for 9964 110 VAC 4387...

Reviews: