Setup Wizard
Don’t be alarmed, the next screen will look exactly the same as
the previous; the exception being that it is now titled PRE-ALERT
ZONE SETUP. The settings are similar, but specific to the two
Collaborators you are setting up. An example of the Collaborator
ID is seen below. Every Collaborator has one, and they should be
noted before installation, they can prove difficult to read from
the ground
In the Pre-Alert Zone Setup, the distance of the zone (as
previously explained) must be set. Additionally, the distance
between the Pre-Alert Zone and the Alert Zone must be
designated. Measure the zones center to center to come up with
this number.
Finally, select whether the two radars within the zone require
collaboration. Leaving this box unchecked will create a zone
where a detection on
either
radar constitutes a collaboration.
Remember, a notification will not be sent off of a single zone
collaboration.
The Flasher Activation and Confirmation Zone Setup pages will
be identical in function. Again, each can be setup with 1 or 2
Collaborators.