SAFETY INSTRUCTIONS
SAFETY OPERATING INSTRUCTIONS
While the machine is working normally, ultrasonic and tank syntony gives a well-proportioned
sound, and no shudder on the surface of the water, yet there is spray made by the tiny bubbles.
If there are discontinuous surges, please add or release a little of washing solution in the tank,
stopping the surges is better for the objects cleaning.
Please read the following very carefully as failure to comply may invalidate your guarantee.
û
DO NOT run the cleaner continuously for more than 30 minutes at a time, as doing so
can damage the internal components.
û
DO NOT operate the unit without fluid in the tank. Always ensure the fluid is no higher
than the max mark. Always ensure there is a minimum depth of 7cm.
û
DO NOT drop any item into the tank as this may cause damage to the transducer.
ü
Always place the items gently into the tank and use the basket whenever possible.
ü
The more items that you place in your cleaning bath the less efficient it will clean. It is
not advised to overlap items. Always allow plenty of clear space between the items.
ü
Keep the lid on during use. This will prevent splashes and reduce evaporation of the
fluid.
ü
Always wear suitable protective clothing, gloves and goggles.
û
DO NOT immerse the machine or power cord in water or other liquid.
û
DO NOT touch the unit if the machine has fallen into water during operation. Remove
the power plug from the socket first.
ü
UNPLUG the power source while filling or emptying the tank.
û
DO NOT spray water or liquid over the device and the control panel
û
DO NOT operate the cleaner without proper grounding.
û
DO NOT place the device on a soft surface, where the vents could be blocked.
ü
Upon completion of the cleaning cycle, turn the heater dial off and isolate the machine
from the electrical supply.
ü
Take care when adding or removing items from the cleaning tank as the fluid is likely
to be hot and displaced fluid can damage the internal components. Any displaced
fluid must be dried up immediately.
ü
In the event of failure/emergency, disconnect the mains supply by removing the plug
from the mains socket.
ü
When servicing, use only Tradequip identical replacement parts. Use of any other
parts will void the warranty. Ensure the Ultrasonic Parts Cleaner is disconnected from
power before servicing.
ü
Use the right product for the job. There are certain applications for which the
Ultrasonic Parts Cleaner was designed. Do not modify the Ultrasonic Parts Cleaner and
do not use the Ultrasonic Parts Cleaner for a purpose for which it was not intended.