background image

TU600-x 

 

 

 

Short Guide TU600-x v0.2, January 2020, ©Trackunit 2020

 

 

 

Installation check and update using  
“Verify my Trackunit” 

 

 

                

         

         

   

 
             

         

         

 

 

 

 
 
 

 

 

 

 

Step 1: Login  

 
- Go to 
http://verify.trackunit.com 
  
- Enter user name and 
password 

 

Step 2: Find unit  

 

- Enter serial number and 
then click “Find” 

 

Step 3: Review 
status  

 

- Time of last received data 
 
- GPS and mobile signal  
 
- Mobile number  
 
- Power supply voltage 
 
- Internal battery voltage 
 
- Status of inputs 1-4 
(on/off) 
 
- Click “Find” again to 
refresh status 

 

Step 4: Basic 
configuration 
options 

 

 

 

- Enter a device name  
 
- Enter engine hours  
 
- Enter start distance  
 
- Select category  
 
- Connect up to multiple 
groups  
 
- Add a note (visible in 
Trackunit Manager)

 

Step 5: Logout

 

 

- Click “Update” to save   
 
- Click “Logout” 

 
 
 
 
 
 

Note

 

 

- Prior to verification, make 
sure the unit is installed 
and active in an area with 
sufficient GPS and mobile 
coverage. 
 

Summary of Contents for TU600-x

Page 1: ...NOTE Model ID TU600 x LTE Cat M1 Cat NB1 2G Short guide TU600 x Version 0 3 January 2020 45 5 mm W 17 9 mm H 122 3 mm L ...

Page 2: ...nstallation example 5 Functionality check LED on the unit 6 Installation check and update using Verify my Trackunit 7 Input filtering INFILT 8 CAN bus termination resistor 9 Troubleshooting 10 Product specifications 11 Temperature range 12 Mechanical specifications 12 Regulatory information and precautions 13 Approvals and Certifications 15 ...

Page 3: ...ber is located on the unit The mobile number and unit serial number are located on the box label It can be peeled off and saved for later use Do not perform installation inside a building Install the unit outside for better GPS and GSM UMTS signal Position the unit as shown for optimal signal conditions Avoid installing the unit directly under a layer of metal or next to wires S N xxxxxx ...

Page 4: ...onnect to the ignition signal mandatory for vehicles and machines 1 Digital input 3 Optional input1 Digital input 4 Can be used for INFILT function Optional input2 Digital output 1 Can be used to control a relay3 4 CAN High Connect to CAN High CAN Low Connect to CAN Low 1 Wire input M8 connector for access control and temperature sensor 1 Supply voltage range 12 48V 2 Active high when min 9 5V DC ...

Page 5: ...TU600 x Short Guide TU600 x v0 2 January 2020 Trackunit 2020 5 Installation example ...

Page 6: ...ork is OK and GPS has valid satellite position No light in LED No power supply Constant red light and no green light in LED Power supply is OK but NO mobile network GPS has NO satellite position Red flashing light and no green light in LED Mobile network is OK GPS has NO satellite position Constant red and green light in LED Power supply is OK but NO mobile network GPS has valid satellite position...

Page 7: ...ta GPS and mobile signal Mobile number Power supply voltage Internal battery voltage Status of inputs 1 4 on off Click Find again to refresh status Step 4 Basic configuration options Enter a device name Enter engine hours Enter start distance Select category Connect up to multiple groups Add a note visible in Trackunit Manager Step 5 Logout Click Update to save Click Logout Note Prior to verificat...

Page 8: ...hours To avoid this situation the digital input 4 pink wire should be connected to the chassis ground on the machine The infilt function should be activated via Verify my Trackunit Activation of input filtering Go to http verify trackunit com NB Enabling the filtering function will disable inputs 1 to 3 when input 4 is on active This can prevent all digital input alarms It will also disable the us...

Page 9: ... multiple CAN devices already attached Default setup without 120 ohm bus termination The 120 ohm termination resister is a software controlled resistor so make sure to use and select the correct TU600 CAN bus profile CAN bus profile is selected in Trackunit Manager and software controls the resistor setup With 120 ohm bus termination directly connected Without 120 ohm bus termination stub connecte...

Page 10: ...egative wire ground wire from the machine battery When off the inputs may register a voltage level and start counting operating hours To avoid this situation the digital input 4 pink wire should be connected to the chassis ground on the machine See Input filtering INFILT section page 8 Technical Assistance If you experience an issue and cannot find the information you need in the product documenta...

Page 11: ...tage 12 48 V DC Absolute maximum voltage range 8 58 V DC continuous Standby consumption GSM receiver active 10 mA 7 mA avg at 12V 24V Consumption during charging an empty battery 225 mA 115 mA max at 12V 24V Charging time for an empty backup battery 4 hours at 25ºC 77ºF Digital inputs 4 Digital outputs 1 CAN inputs High Low 2 Access control input M8 connector 1 ...

Page 12: ...red Storage 40ºC to 70ºC Shorter battery lifetime must be expected when storage and operation occur at extreme temperatures Mechanical specifications Length 122 3 mm 4 8 in Width 45 5 mm 1 8 in 50 1 mm incl cradle 1 9 in Height 17 9 mm 0 7 in 22 7 mm incl cradle 0 9 in Cable length 170 cm 5 6 ft Environmental class IP67 With HW Shield IP66k IP69k PN 7402 9551 and 7402 9552 Weight 66 g excluding ca...

Page 13: ...itters and complies with the essential requirements of Part 2 1091 15 247 22 24 27 and 90 of the FCC rules and with RSS GEN RSS 102 RSS 130 RSS 132 RSS 133 RSS 139 and RSS247 of the Industry Canada requirements Environmental The TU600 products complies with the SAE J1455 environmental conditions for heavy trucks when mounted in the vehicles Additionally compliance to shock and acceleration by IEC ...

Page 14: ...agnetic compatibility IV UN regulative ECE R10 EMC rev 5 in accordance with EU regulation 661 2009 for Electronic Sub Assembly ESA NOTE Harmonized standards under the directive 2014 30 EU have been applied Statement for ISO 13849 1 The TU600 x are when installed not a vital part in the machine safety system but it can be used as access control immobilizer if paired with a keypad e g DualID II or I...

Page 15: ...made to this equipment not expressly approved by Trackunit may void the FCC authorization to operate this equipment FCC IC Radiofrequency radiation exposure Information This equipment complies with FCC IC radiation exposure limits set forth for an uncontrolled environment This equipment may be installed and operated with minimum distance of 20 cm between the radiator and your body This transmitter...

Page 16: ...fied for PTCRB interoperability with mobile networks 77390 Trackunit TU600 5 HW 1 000 SW 60 012 SVN 7 Japan The TU600 x model is certified for Japan under ID n R 003 180062 R 209 J00306 T D180034003 This device is granted pursuant to the Japanese Radio Law 電波法 当該機器には電波法に基づく 技術基準適合証明等を受けた特定無線設備を装着して いる This device should not be modified otherwise the granted designation number will become invalid 本...

Page 17: ...s Chile Regulatory label Asia Myanmar Certified countries The TU600 5 model is additionally certified for countries that has no regulatory label requirements India Kuwait Qatar Saudi Arabia The certificates can be requested at Trackunit A S for use for import declarations ...