background image

SPECIFICATIONS

Battery: 

2 each AA alkaline batteries  

included 

(see battery replacement section)

ABOUT THE MEMORY

Minimum and maximum memories are 

NOT programmable (see Alarms).

 

The minimum humidity, temperature, and dew-point 

recorded into memory are the minimum humidity, 

temperature, and dew-point achieved since the 

last time the memory was cleared.  The maximum 

humidity, temperature, and dew-point recorded into 

memory are the maximum humidity, temperature, 

and dew-point achieved since the last time the 

memory was cleared.  The minimum and maximum 

memories are maintained over the period since the 

memory was cleared.  

VIEWING THE MIN/MAX MEMORY

To view the maximum humidity, temperature, and 

dew-point memory, press the MIN/MAX button once 

on the side of the unit.  The maximum humidity, 

temperature, and dew-point reading achieved will be 

displayed (“MAX” will appear on the display).

Press the MIN/MAX button a second time, within 

16 seconds, to view the minimum humidity, 

temperature, and dew-point achieved (“MIN” will 

appear on the display).

Note:

 Sixteen (16) seconds after pressing the MIN/

MAX button, the unit automatically returns to the 

current humidity, temperature, and dew-point reading.
Press the MIN/MAX button a third time, within 

16 seconds, to return to the current humidity, 

temperature, and dew-point reading.

CLEARING THE MAXIMUM MEMORY

The maximum humidity, temperature, and dew-point 

memory may be cleared.  To clear the maximum 

memory, press and hold the RESET button on the 

side of the unit while the maximum memory value 

is being displayed (see the “Viewing the Memory” 

section).  The display will show “- -” for approximately 

5 seconds and will then display the current reading.

CLEARING THE MINIMUM MEMORY

The minimum humidity, temperature, and dew-point 

memory may be cleared.  To clear the minimum 

memory, press and hold the RESET button on the 

side of the unit while the minimum memory value 

is being displayed (see the “Viewing the Memory” 

section).  The display will show “- -” for approximately 

5 seconds and will then display the current reading. 

SELECTING °C OR °F

To display the temperature/dew-point reading in 

Fahrenheit or Celsius, slide the °C/°F switch, located 

on the back of the unit, to the desired position.

ALARMS

Alarm may be set for humidity only within the range 

of three RH values 55%, 60% and 65%. To set the 

unit to alarm when the ambient humidity increases 

to 55% RH and above, slide the switch located on 

the back of the unit to 55%. To set the unit to alarm 

when the ambient humidity increases to 60% RH and 

above, slide the switch located on the back of the unit 

to 60%. To set the unit to alarm when the ambient 

humidity increases to 65% RH and above, slide the 

switch located on the back of the unit to 65%. 

VISUAL ALARM INDICATOR

The unit will visually indicate an increase in ambient 

humidity above set alarm points when the switch 

located on the back of the unit is set to AL. OFF. A 

red LED on the front of the unit will flash if conditions 

rise above a set alarm point.  When the ambient 

conditions fall below the set alarm point the LED will 

no longer flash.

AUDIBLE ALARM INDICATOR

To set the unit to audibly alarm at set points. Slide the 

switch located on the back of the unit to AL. ON. An 

alarm will sound and the LED will flash if the current 

ambient humidity is above the set alarm point. When 

ambient conditions fall below the set alarm point, the 

audible alarm will no longer sound and the LED will no 

longer flash.

WALL MOUNTING THE UNIT

Set a screw into the wall at the desired location.  Do 

not set the screw flush to the wall, the head of the 

screw will need to slip into the receptacle on the back 

of the unit.  Once the screw has been properly set, 

hang the unit in place by sliding the receptacle on the 

back of the unit over the head of the screw.

USING THE SUPPLIED 

BENCH STAND

When standing the unit on 

a desk or lab bench, use the 

supplied BENCH STAND  

(see Fig 1).
Place the stand on the desk 

and affix the unit as shown.

Fig 1.