4-12
PM SW 175/250 Dual Diagram
A
B
C
D
AC
HOT
IN
1
AC
HOT
IN
2
NEUTRAL
IN
1
(GENERA
T
O
R
IN)
EXTERNAL
BA
TTER
Y
TEMP
R
Y
8
COM
J2
R
Y10
RY
1
1
RY
8
N
O
NO
RY7
NC
LOWER
COM
COM
NC
RY11
NO
NC
COM
NO
TB2
NO
NC
COM
RY10
UPPER
RY9
AC
CONNECTIONS
NEUTRAL
IN
2
NEUTRAL
OUT
AC
HOT
OUT
FROM
AC
UTIL
OR
GENERA
T
HOT
FROM
AC
UTIL
OR
GENERA
T
HOT
SOLAR
ARRA
Y
1
(-)
PMO-ELEC-MOD
Solar Array (+)
Battery (-)
Solar Array (-)
Battery (+)
C40 FRONT VIEW
C40 FRONT VIEW
SLAVE SW INVERTER #2
MASTER SW INVERTER #1
C40 FRONT VIEW
C40 FRONT VIEW
C40 FRONT VIEW
C40 FRONT VIEW
1
2
3
4
C40 FRONT VIEW
AC
LOADS
5
HAL 9000
HEADINGS
ITEM
MENU
SET POINTS
ON/OFF
MENU
MENU
GEN
MENU
LINE TIE
INVERTING
RESET TO
FACTORY
DEFAULTS
CONTRAST
control panel
OVER CURRENT
AC2 IN GOOD
FLOAT
AC1 IN GOOD
BULK
ERROR
HAL 9000
HEADINGS
ITEM
MENU
SET POINTS
ON/OFF
MENU
MENU
GEN
MENU
LINE TIE
INVERTING
RESET TO
FACTORY
DEFAULTS
CONTRAST
control panel
OVER CURRENT
AC2 IN GOOD
FLOAT
AC1 IN GOOD
BULK
ERROR
AC
HOT
IN
1
NEUTRAL
IN
2
AC
HOT
IN
2
NEUTRAL
IN
1
(GENERA
T
O
R
IN)
EXTERNAL
BA
TTER
Y
TEMP
R
Y
8
COM
J2
R
Y10
RY
1
1
RY
8
N
O
NO
RY7
NC
LOWER
COM
COM
NC
RY11
NO
NC
COM
NO
TB2
NO
NC
COM
RY10
UPPER
RY9
AC
CONNECTIONS
FROM
AC
UTILITY
OR
GENERA
T
O
R
GROUND
BA
TTER
Y
(-)
BA
TTER
Y
(+)
AC
HOT
IN
1
NEUTRAL
IN
2
AC
HOT
IN
2
NEUTRAL
IN
1
(GENERA
T
O
R
IN)
EXTERNAL
BA
TTER
Y
TEMP
R
Y
8
COM
J2
R
Y10
RY
1
1
RY
8
N
O
NO
RY7
NC
LOWER
COM
COM
NC
RY11
NO
NC
COM
NO
TB2
NO
NC
COM
RY10
UPPER
RY9
AC
CONNECTIONS
BA
TTER
Y
(+)
SOLAR
ARRA
Y
1
(+)
SOLAR
ARRA
Y
1
(+)
SOLAR
ARRA
Y
1
(+)
SOLAR
ARRA
Y
1
(+)
FROM
AC
UTILITY
OR
GENERA
T
O
R
NEUTRAL
Battery (+)
PV (+)
Battery (+)
PV (+)
Battery (+)
PV (+)
SOLAR
ARRA
Y
1
(+)
SOLAR
ARRA
Y
1
(+)
T
O
AC
LOADS
SOLAR
ARRA
Y
1
(+)
AMPS 70
BATTERY TEMP 35C
VDC 24.1
AMPS 70
BATTERY TEMP 35C
VDC 24.1
11
11
PM SW 175/250 Dual Diagram
All configurations use 6 AWG THHN wire for AC and PV wiring. Inverter
cables are 4/0 for SW2512, 4024 and 5548. Use 2/0 for SW4048. Use
red heat shrink for positive and black heat shrink for negative. Each
assembly also includes the door (not shown). Refer to the individual
components for assembly descriptions. Follow the assembly sequence as
shown on the reverse side of this page. All AC & DC breakers are located
in the top cabinet. Lower cabinet contains PV Solar Array DC breakers if
equipped with C40 Controllers. Install inverters last, beginning with the
bottom cabinet, after securing the modules in place. Use the fasteners
listed in A, B, C, D. Starwashers are used to lock fasteners and assure
ground continuity.
#
Qty
Part No.
Description
1
2
IOX60
AC input/output/bypass disconnect
2
2
SLIDER
3
1
NEUTRAL
AC neutral and ground bonding block
4
AR
C40
optional
5
1
DCBB
DC ground bonding block
6
2
COVER
7
2
2079-250
250-amp DC breaker or
2116-175
175-amp DC breaker
8
AR
2298
PV Solar DC disconnects
9
AR
C40’s
10
AC connections detail
11
2
Sinewave inverters
A
6
425
¼ - 20 X ¾” HH SS bolt
B
12
2147
¼” external tooth starwasher
C
12
468
¼” flat washer
D
6
444
¼ - SS HH nut