Assembly Instructions | ILM Servo Kits
23
Edition 03/2021 EN
Assembly
►
Cure the adhesive for approx. 10 minutes in the curing oven. Make sure that no ex-
cess adhesive can bond to the floor of the curing oven.
►
Attach the 0.9 mm dispensing needle to the disposable syringe.
►
Fill the disposable syringe (e.g. with LOCTITE 9497).
►
Inject adhesive into the hole (item 2 in Fig. 12) in the housing until the adhesive
emerges from the hole on the opposite side. Twist the needle a little from side to
side as you inject to evenly distribute the adhesive.
►
Remove the adhesive that emerges and seal both holes with Kapton tape.
►
Place the stator in the curing oven so that it cures fully. Follow the manufacturer’s