![TQ-Systems TQMa8Xx Preliminary User'S Manual Download Page 18](http://html1.mh-extra.com/html/tq-systems/tqma8xx/tqma8xx_preliminary-users-manual_1146557018.webp)
Preliminary User's Manual l TQMa8Xx UM 0002 l © 2018, TQ-Systems GmbH
Page 14
3.2.4
Interfaces
(TBD)
3.2.5
Reset
Reset inputs and outputs are available on the TQMa8Xx connectors.
The following table describes the reset and config signals available on the TQMa8Xx connector.
Table 10:
Reset and config signals
Signal
Dir.
Power domain
Function
TQMa8Xx
Remark
RESET_IN#
I
VDD_ANA1_1P8
i.MX 8X reset input
X2-32
Low Active signal
Deactivate: float or connect to 1.8 V / 3.3 V
RESET_OUT#
O
External defined
Open-Drain output
X2-34
Low Active signal
Requires Pull-Up on carrier board (to max. 6.5 V)
IMX_ONOFF
I
V_SNVS_CAP
ON / OFF signal of i.MX 8X
X1-118
Low Active signal
Deactivate: float
Illustration 8:
Block diagram Reset