background image

 

 

19 

2

  

It would popup the dialog box later.     

 

 

3

 

Click 

‘’Next’’ to install, or install the specific location from the list.

 

 

Summary of Contents for AMT506

Page 1: ...AMT506 COLORIMETERS Professional Color Detection Tool Rubber Spray paint Hardware Building Electrical Printing Suitable for multi industry s color analysis and quality control of Color difference ...

Page 2: ...easured 9 5 Function menu 5 1Test setting 10 5 1 1 Single mode 10 5 1 2 Average mode 11 5 2 Tolerance setup 10 5 3 Check Call out 12 5 4 Calibration setting 12 5 5 PC communication 13 5 6 System setting 13 5 6 1 Time setting 14 5 6 2 Formatting 14 5 6 3 Language selection 15 6 Other function introduction 6 1Save Check and call out 15 6 2Micro printerto print 16 7 Function explaining 7 1 Standbyand...

Page 3: ...ng instructions 21 9 2 Interface description 21 9 3 Save and open 21 9 4 Standard management 22 9 5 Tolerance judgment 22 9 6 System setup 23 9 7 Print function 23 9 8 Download the data of instrument 24 9 9 Help 24 10 Troubleshooting guide ...

Page 4: ...sy to control A variety of light and color space modes meet special needs of different measurement conditions Two calibrations white calibration and zero calibration the measurement data are more accurate and stable 1500 sets of data storage space can check callout upload the data at any time Professional color quality software would assist the color analysis and quality control 1 3 Applied Color ...

Page 5: ...ronment lon gterm this would cause instrument accuracy reduced and performance fault Do not use the AMT506 in areas where dust smoke corrosive gases into the instrument inside it may cause the damage of instrument Do not use the AMT506 near equipment which produces a strong magnetic field it would cause data exception of instrument The instrument belongs to precision instrument other person is not...

Page 6: ... 2 Architectural feature and working principle 2 1 Architectural feature 2 1 1 Colorimeter 1 USB port 2 Micro printer port 3 AC adapter port 4 Test key 5 Keyboard 6 LCD 7 On off 8 Dust cap 2 1 2 Keyboard ...

Page 7: ...ard and sample formula as follows E L 2 a 2 b 2 1 2 E The total color difference L L Sample L S tandard L Whitish L Blackish a a Sample a Standard a Reddish a Greenish b b Sample b Standard b Yellow b Bluish Basic judgment of Color difference Color difference range Basic judgment of Color difference 0 0 25 E Very small or none exact match 0 25 0 5 E Very small acceptable match 0 5 1 0 E Small to m...

Page 8: ...E ab L a b L C H XYZ Operating language Simplified Chinese Traditional Chinese English Storage space Standard 50 sets 30 sets color difference data under a standard data Standard illuminant D65 D50 F11 C Calibration White calibration Zero calibration Repeatability Standard deviation within E ab 0 08 When the white calibration plates is measured 30 times and averaged Weight 330g Without batteries S...

Page 9: ... the test interface the default mode Illuminant and Color space is single mode D65 10 and L a b The measuring aperture should closely fit the measured object then press the Test key to start standard test as shown below 4 3 Save Please press the Enter key to enter the sample test after the standard measured and you can press Save key to save the standard sample it would display the standard number...

Page 10: ...e key to save the color difference data it would display the color difference number in the upper right of the current interface Note Before you store the color difference data you should store the standard data first 5 Function menu Press the Menu key to enter the function menu interface 6 functions to select Test setup Tolerance setup Check Call out Calibration setup PC communication and System ...

Page 11: ...rface select Illuminant selection Color space selection Test mode Notes It would automatically retain the settings if you select to exit 5 1 1 Single mode It would enter the sampling test interface after you select the Single mode you can do sampling test directly the default test mode is Single mode ...

Page 12: ... large areas surface According to the actual situation we can press the arrow key to select the appropriate average times as shown below After select the desired average times press the Enter key to enter the Average mode interface for testing Notes The test times and the sample measurement times are the same as shown below ...

Page 13: ... the tolerance setup interface the default data is 0 5 you can press arrow keys to adjust the tolerance 5 3 Check Call out According to the different selection of the color space you can check the stored standard data and its corresponding color difference data in the L a b L c h and XYZ of the three color space modes Note Select and check the data in different color space the Menu key can call ou...

Page 14: ...h this step it would enter test interface 5 5 PC communication The AMT506 can connect the computer through our software it would extend more functions of the instrument Note After you enter the PC communication interface then the instrument can connect with the computer software as shown below ...

Page 15: ...e Time setup Formatting and Language setup in this interface 5 6 1 Time setup Press the Year Month Date Hour and Minute to set of the Time setup interface and press the arrow key to correct press Enter key to finish the setting ...

Page 16: ...r to start formatting and the Esc to exit Warning Be careful All data would be lost if you confirm formatting 5 6 3 Language selection There are Simplified Chinese Traditional Chinese and English three languages to select please according to the demand to select the operation language ...

Page 17: ...nd please formatting it Press the Enter key to enter the color difference test interface for comparison test in this interface please press the Save key to save it we can save 30 sets color difference data use the symbol A to represent it When the record more than 30 sets it can t store the data now please formatting it then you can save the data Note Press the arrow key to check the data after yo...

Page 18: ...u don t use it for 5 minutes The instrument will wake up to the previous interface for press any key 7 2 Battery test It would lead to the test data anomalies if the working battery has not enough power and the AMT506 will automatically popup a prompt interface remind us to change the battery Now we should change the battery immediately or it may affect the measure accuracy 7 3 Safety instruction ...

Page 19: ...ur own drive 8 2 Connection the AMT506 Enter the PC communication interface and select the PC communication it would appear the USB connection interface when you press Enter key 8 3 USB installation 1 Put the CD to the CD ROM and insert the USB cable to the USB port of AMT506 it would appear Found new hardware as shown below ...

Page 20: ...19 2 It would popup the dialog box later 3 Click Next to install or install the specific location from the list ...

Page 21: ...20 4 Click Browse to find the Driver File in the CD ROM directory and click Next the installation wizard will automatically install the driver 5 Click Finish the driver has finish the installation ...

Page 22: ... it need re connect just need press the Connect no need to close the software 9 2 Interface description The main interface has two parts toolbar and 5 functions 1 Related information you can set it in the software system and it would display it when you print 2 Measurement interface show the related data of the standard measured and sample measured 3 Color simulation display the simulation color o...

Page 23: ...ent 2 Excel file xls you can edit and print it after you saved but it can t callout again Notes We need store the files first and the data can open in next 9 4 Standard management Save the standard sample first if the measured standard data need test in next measurement you need open the management and callout the standard data and continue the measurement ...

Page 24: ...termine whether the color difference meet the requirement according to your tolerance range 9 6 System setup Setting the related information of the measured object and it would form the complete measurement information it would also automatically generate the relevant information when you print the report ...

Page 25: ...of sample and standard in two illuminant source modes 2 Summary report The output of each color difference data in the same standard sample batch 3 Color difference histogram color difference analysis of the summary 9 8 Download the data of instrument Press the Dwenload button we can download the instrument datas to computer and the data also can store or callout the standard data ...

Page 26: ...d standard data and now press Sample data after it you can check the color difference data 9 8 1 Save and Callout Press the Save to file after you download the data then press Save standard the standard data would save in management 9 9 Help Check the software version information and the software operation instructions in this function ...

Page 27: ...suring smoothly B the object is too thin or it has other color in reverse side B Pad the whiteboard rev erse side or pad some white measurement C uneven color of the obje Ct or color mixed C Avoid the uneven color position or select the average measurement D no power of the battery D Change the battery or use the DC adapter E the instrument no calibration for long times E Please calibration first ...