control

The product is optimised for a lifespan >50kh in a 40°C atmosphere.
In strobe mode, the strobing time is directly equivalent to the time during which the strobe entry is activated.

Strobe PnP

 & 

nPn

PnP : from 5 to 24V for 100% ON. From 0 to 1V for 100% OFF.
nPn : less than 1V for 100% ON. Above 2V for 100% OFF. Max 20V.

Strobe mode

STROBE INPUT

> 2 ms

2 ms

15 µs

15 µs

15 µs

15 µs

LIGHT

30%

100%

Triggering input 

> 2 ms

Triggering input 

< 2 ms

1 ms

Strobe mode : LED are supplied in Overdrive.

Continuous mode : after 2ms in Overdrive, LED are supplied at a safe level for use in continuous mode.

d max (%)

t max

f max

Cw

100%

CW

N/A

Strobe

5%

2 ms

750 Hz

D : Duty Cycle
t : pulse duration
f : frequency

Summary of Contents for BLBAR+

Page 1: ...lowed at all times TPL Vision will not be held responsible for problems caused by using the product contrary to these instructions and the Warranty will be deemed invalid TPL Vision can provide guidance notes about the nominal distance to minimize eye risks unpacking Products are packed in our factory using suitable materials for a safe transport through the usual means of trans portation in Franc...

Page 2: ...er LED indicator Set at equal distance n Length Lg 600 mm 2 M4 nuts n 600 mm Lg 1250 mm 3 M4 nuts Nuts M4 supplied Screws M4 not supplied During the set up the light has to be switched off and unplugged Please use the delivered nuts and insert them in the groove located in the back of the light The light will be better fixed if you spread the attachment points as indicated on the scheme above You ...

Page 3: ...le 24V signal power M12 4 male points T coding M12 5 male points M12 5 female points M12 4 male points T coding M12 5 male points M12 5 female points 24V Use an extension cable male female M12 M12 5 x 0 342 Front view Top view M12 5 female Points M12 5 Male Points M12 4 Male points T Coding ...

Page 4: ...brown 24V 24V 3 GND GND blue The M12 male connector 5 points is compliant with the M12 female connector 4 points In that case the dimming option is not available Voltage drop Dimensions 125 250 375 500 625 750 875 1000 1125 1250 Max voltage drop in the bar V 0 01 0 03 0 06 0 12 0 18 0 26 0 35 0 46 0 58 0 72 Power supply cable 4x1 5 max length for acceptable voltage drop m 150 150 150 150 138 112 9...

Page 5: ...rom 0 to 1V for 100 OFF NPN less than 1V for 100 ON Above 2V for 100 OFF Max 20V Strobe Mode STROBE INPUT 2 ms 2 ms 15 µs 15 µs 15 µs 15 µs LIGHT 30 100 Triggering input 2 ms Triggering input 2 ms 1 ms Strobe mode LED are supplied in Overdrive Continuous mode after 2ms in Overdrive LED are supplied at a safe level for use in continuous mode D max t max f max CW 100 CW N A Strobe 5 2 ms 750 Hz D Du...

Page 6: ... supply 125 250 375 500 625 750 875 1000 1125 1250 Power needed in Strobe W 48 96 144 192 240 288 336 384 432 480 Power needed in Continuous Working W 11 1 22 2 33 3 44 4 55 5 66 6 77 7 88 8 99 9 111 Min functioning Voltage 20V in the light input Normal functioning Voltage 24V in the light input 10 Max functioning Voltage 30V in the light input Dimming 0 10V 30 50 70 100 0 2 4 6 8 10 VOLTS Dimming...

Page 7: ...cannot be implemented supply the operators with glasses class 4 available for sale at TPL Vision or with a dedicated protective mask that will stop the lighting radiation Forbid or limit the direct access to the lighting source exposure into the radiation axis Establish a security perimeter so as to prevent the operators from approaching the lighting source beyond the recommendations of the manufa...

Page 8: ...se School Road Charing Kent TN27 0JW UK Tel 44 0 1738 310 392 www tpl vision com Features and presentations liable to changes without notice Documentation valid from June 2017 until further notice Ref UG 010103 C1 2020 09 edition ...

Reviews: