background image

INSTALLATION

 INSTRUCTIONS

ATTENTION: Read carefully
before attempting to install
or operate the heater.

3480/RCH SERIES

GENERAL INFORMATION

MOUNT HORIZONTAL POSITION ONLY.
DO NOT INSTALL ANY CLOSER THAN 12” TO NEAREST WALL
CHECK TO SEE THAT SERVICE VOLTAGE IS THE SAME AS HEATER VOLTAGE.
ALL WIRING MUST CONFORM TO THE NATIONAL ELECTRIC CODE AND EXISTING LOCAL CODE
REQUIREMENTS.

FORM: 9480

ECO 1-5917

NOTE: If plaster frame is required for installation
order it as an option.

WARNING:

 To avoid the risk of fire, shock or personal

injury; make sure that the power source is disconnected
before attempting to install, service, clean or disas-
semble the heater or any of its components. If the power
disconnect is out of the line of sight, lock in in the open
position and tag it to prevent the application of power.

INSTALLATION INSTRUCTIONS:

1. Detach heater unit from the ceiling mounting plate

in the recessed can by disengaging the stabilizing
arms on ceiling plate from the heater unit.
4 - 

#8 drive screws.

2. For a dropped or suspended ceiling, anchor the

recessed can useing either threaded rod, or wire in
an approved method that is sufficient to support
the heater assembly such that the bottom edge of
the recessed can just rest on the T-bar frame. For
plaster or similar finished ceilings, the can should
be installed so the flanges (of the can) are even
with the interior finish or ceiling line.

3. For plaster or other similar finish ceilings attach

the PT3480 accessory plaster frame to the
recessed can using 8 - 

#8 x 3/4 drive screws

.

(detail “AA”)

4. Hang heater unit from two stabilizing arms on the

ceiling mounting plate in the can. Be sure to
engage the two arms with the hooked ends on the
ceiling plate with the slots in the heater plate.

5. Connect the heater leads with their corresponding

supply leads in the outlet box (75

O

C wire must be

used). The outlet box is permanently attached to
the top of the can. After this is complete, install the
ceiling plate access hole cover with
2 - 

#8 drive screws

 which have been provided.

6. Swing the heater unit up to the ceiling mounting

plate and secure with 4 - 

#8 drive screws

 that have

been provided. Do this by placing one screw in
each of the four stabilizing arms on the ceiling
plate.

7. Install heater exterior grille by attaching it directly to

the heater unit. Rotate the exterior grille so that the
two 1/4” dia. holes in the exterior grille aligne with

     the manual reset limit control located on the bottom
     of the venturi of the heater assembly, also make
     alignements so that the venturi of the heater
     assembly  is on the outside the venturi of the
     exterior grille. Secure to the four bracket arms on
     the heater case with 4 - 

10/32 x 3/4 button head

     machine screws

 provided.

IMPORTANT: OWNER SHOULD RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE

1

REV. 06/08

Summary of Contents for 3480 Series

Page 1: ...uld be installed so the flanges of the can are even with the interior finish or ceiling line 3 For plaster or other similar finish ceilings attach the PT3480 accessory plaster frame to the recessed ca...

Page 2: ...wer to the unit If fault continues disconnect power and check for causes THERMAL CUTOUT IDENTIFICATION All 480V Models employ a automatic limit control 208 240 and 277V models may employ zero volt or...

Page 3: ...J3485 K3485 P3482 P3483 P3484 P3485 Y3484 Y3485 208 1 240 1 277 1 208 1 240 1 277 1 208 1 240 1 277 1 208 1 240 1 277 1 208 3 240 3 208 3 240 3 480 1 480 1 480 1 480 1 480 3 480 3 2000 2000 2000 3000...

Page 4: ...08 240 OR 277V HEATERS WD 1 WD 2 WD 3 WD 4 WD 5 WD 6 WIRING DIAGRAM FOR SINGLE PHASE 208 240 OR 277V HEATERS WITH DISCONNECT SWITCH WIRING DIAGRAM FOR SINGLE PHASE 208 240 OR 277V HEATERS WITH DISCONN...

Page 5: ...R R1 OR R2 option NOTE CONTROL VOLTAGE R LINE VOLTAGE R1 24 VAC R2 120 VAC WIRING DIAGRAM FOR SINGLE PHASE 208 240 OR 277V HEATERS WITH CONTROL RELAY FAN DELAY AND DISCONNECT SWITCH R R1 OR R2 option...

Page 6: ...VOLTAGE CONTROL COIL AND FAN DELAY WIRING DIAGRAM FOR THREE PHASE 208 240V HEATERS WITH DISCONNECT SWITCH RELAY WITH LINE VOLTAGE CONTROL COIL AND FAN DELAY WD 17 WD 18 WIRING DIAGRAM FOR THREE PHASE...

Page 7: ...K WHITE 277V ONLY REMOTE MTD RELAY BLACK BLUE YELLOW HEATER SUPPLY 1 208 240V TO LOW VOLTAGE ROOM THERMOSTAT 57912 002 F 208V 57912 003 H 240V CRIMP NUT WD 19 WD 20 RELAY CONNECTION CONNECT THE YELLOW...

Reviews: