Parameter Summary – Digital Parameters (3-_)
Parameter
Description
Range
Default Setting User Setting
3-0
Source of Operation
Command
0: Operation determined by
digital keypad
1: Operation determined by
external control terminals,
keypad STOP is enabled
2: Operation determined by
external control terminals,
keypad STOP is disabled
0
3-1
Digital Inputs 1 & 2
(DI1 & DI2)
0: DI1 - FWD/STOP, DI2 – REV/
STOP
1: DI1 - RUN/STOP, DI2- FWD/
REV
2: DI1 - RUN momentary
(N.O.latching input)
DI2 - FWD/REV, DI3 - STOP
momentary (N.C. latching
input)
0
3-2
Digital Input 3 (DI3)
0: Input Disable
1: External Reverse
2: External Jog
3: External Reset
4: Speed Hold
5: Increase Speed
6: Decrease Speed
7: External Fault (N.C.)
8: External Fault (N.O.)
7
3-3
Digital Input 4 (DI4)
2
3-4
Output Contact
This N.O. dry contact
closes when the selected
range occurs.
Contact rating:
120VAC/24VDC/5A
230VAC/2.5A
0: Drive Running
1: Drive Fault
2: At Speed
3: Zero Speed
0