Lightening Protection
Extremely high voltage currents can be produced instantly when lightning occurs and the air
in the electric discharge path can be instantly heated up to 20,000
℃
. As this instant current
is strong enough to damage electronic devices, more effective lightning protection measures
should be taken.
Ensure the rack and device are well earthed.
■
Make sure the power socket has a good contact with the ground.
■
Keep a reasonable cabling system and avoid induced lightning.
■
Use the signal SPD (Surge Protective Device1 when wiring outdoor.
■
Note:
For detailed lightning protection measures, please refer to
Chapter 3
Lightning Protection
.
Installation Site
S
When installing the device on a rack or a flat workbench, please note the following
items:
The rack or workbench is flat and stable, and sturdy enough to support the weight
■
of 5.5kg at least.
The rack or workbench has a good ventilation system. The equipment room is well
■
ventilated.
The rack is well grounded. Keep the power socket less than 1.5 meters away from
■
the device.
111 Installation Tools
Phillips screwdriver
■
ESD-preventive wrist wrap
■
Cables
■
Note:
These tools are not provided with our product. If needed, please self purchase
them.