Installation Guide
Indoor/Outdoor Access Point
EAP225-Outdoor
EAP110-Outdoor
Overview
Package Contents
Passive PoE Adapter
(Mounting Bracket Included)
Power Cord
M3×28 Plastic Wall
Anchors(Qty.4)
M3×20 Self-tapping
Screws (Qty.2)
The Panel of EAP
Panel Layout
EAP
RESET
Shielded Ethernet
Port LAN
Note:
EAP225-Outdoor does not support the Remote Reset feature.
LED Status
Indication
Solid green
The device is initializing or working properly .
Flashes red
System errors. RAM, Flash, Ethernet, WLAN or
firmware may be malfunctioning.
Flashes yellow
Firmware update is in progress. Do not disconnect
or power off the device.
Double flashes
red,
green, yellow
The device is being reset to its factory default
settings.
Flashes green twice
Initialization is completed.
SYS LED Explanation
Passive PoE Adapter
Power LED:
On: Power on
Off: Power off
Remote Reset:
Press and hold for 8 seconds
to reset the EAP to its factory
default settings.
A DHCP server (typically a router) with DHCP function enabled is required to
assign IP addresses to the EAPs and clients in your local network.
Clients
EAP
EAP
EAP
PC
Switch
Router
Internet
EAP Controller
Lightning and ESD Protection
Before mounting EAP, you should consider Lightning and ESD
Protection to ensure safety.
Proper grounding is extremely important for outdoor devices. By
using a shielded CAT5e (or above) cable for connection, you can
reduce the damage of ESD attacks.
Hardware Installation
Mount EAP
The EAP can be pole-mounted or wall-mounted when working
independently.
The EAP can be mounted on an external antenna when
working with an external antenna.
Option 1: Pole Mounting
Lead the end of the pole mounting
strap through the back of the EAP.
Step 1:
Position the EAP and wrap the pole
mounting strap around the pole.
Feed the end through the
screw-block and tighten the strap
until the EAP is secure.
Step 2:
Connect the antennas to the EAP.
Step 3:
Option 2: Wall Mounting
Step 4:
Connect the antennas to the EAP.
Step 1:
Place the mounting bracket (for
EAP) in the right position. Mark two
positions for the screw holes .
Drill two 6mm holes for the screws
at the marked positions.
Step 2:
Insert the plastic wall anchors into
the 6mm holes. Align the bracket
(for EAP) to the plastic wall anchors
and drive the self-tapping screws
into the anchors through the
bracket (for EAP).
Step 3:
Align the mounting tabs on the
back of the EAP with the slot of
the mounting bracket (for EAP).
Push and slide the EAP downward
until it locks into place.
Antennas (Qty.2)
Mounting Bracket
(for EAP)
Installation Guide
Installation Guide
Indoor/Outdoor Access Point
Pole Mounting Strap
Waterproof Rubber
Insert
M3×16 Self-tapping
Screws (Qty.2)
Typical Network Topology
© 2017 TP
-Link
7106507814 REV3.0.1
EAP
Grounded 3-wire
Power Outlet
Grounded PoE Adapter
Shielded CAT5e (or above)
Cable