he
cy
to
es
ck
The wick height adjuster knob, with three small holes marked
1
,
2
, and
3
, can be
seen. The stem pin is engaged in one of the holes. Pull the control dial toward you
and change the location of the pin from
1
to
2
, or from
2
to
3
. Each step from
pin
1
to
2
will raise the maximum wick height by 2 mm per step. After this
adjustment, replace the wick adjuster knob.
When suitable flame length can no longer be achieved even on pin position 3, it is
time to clean and replace the wick. AFTER REPLACING THE WICK, CHECK THE
OPERATION OF THE AUTOMATIC EXTINGUISHER BEFORE LIGHTING YOUR
HEATER.
NOTE: NEVER use positions
2
or
3
until position
1
no longer gives adequate
flame length.
EXTINGUISHING THE FLAME
1. Turn the wick adjuster knob counterclockwise until it stops. This requires about a
half turn. At this point, the flame is completely extinguished and the heater is off.
NOTE: DO NOT use the automatic extinguisher to routinely turn off the heater.
Automatic extinguishing should occur only when the heater is jarred or
tipped. Using the automatic extinguisher to turn off the heater will cause
odor, smoke and soot.
2. Make sure the flame is out completely.
3. DO NOT try to relight the heater for at least three (3) minutes after extinguishing it
off as this may cause smoke and odor.
MANUAL SHOTOFF
When quick shutoff is necessary, push the manual shutoff button.
NOTE: For routine turn-off, DO NOT use the Manual Shutoff or activate the
Automatic Extinguisher by jarring the heater. These methods may cause
unwanted odor, soot and smoke. Only the wick adjuster knob should be
used for normal shotoff.
Wick hight
adjuster knob
Stem pin
8
RCA-37WX_US.qxd 15.10.22 10:26 ページ 8
used for normal shutoff.
MANUAL SHUTOFF