12. Put the wick holder back into position.
13. Make certain the top plate of the wick holder and
the top of primary air tube are the same height. If
they are uneven, the flames tend to be uneven,
too. And tighten the four (4) wing nuts around the
wick holder.
Note: The space between the wick holder and
the primary air tube should be even all
around.
14. Operate the wick adjuster knob to be sure the wick moves smoothly up and
down. After replacing the wick, check the operation of the automatic
extinguisher.
15. Wick height on position
1
of wick life extender should be 8 mm (5/16 in.) when
wick adjuster knob fully clockwise. Be sure to check.
Pull out the wick adjuster knob from the wick adjuster shaft.
16. Replace the cabinet and secure it into position.
17. Tighten the three (3) screws at the side and rear of the cabinet by using the
screwdriver.
Space