SECTION B:
SAFETY TIPS FOR OPERATION
CAUTION: Heater and vent pipe system must be properly installed before operation. Please follow
instructions under “Installation”, Section I.
1.
Never use any fuel other than ASTM D3699 1-K Kerosene, ASTM D396 Low
Sulfur No.1 Fuel Oil, or ASTM D975 Ultra Low Sulfur Diesel (ULSD).
NEVER USE GASOLINE. Use of gasoline can lead to uncontrollable flames,
resulting in destructive fire.
2.
Due to high surface temperatures, keep heater away from children, furniture
and clothing while in operation (See Page 22).
3.
To prevent abnormal operation and prolong heater life, be sure to perform
routine maintenance (See Pages 12-13).
4.
Never store or transport fuel in other than a metal or plastic container that is
clearly marked “KEROSENE”, “NO.1 FUEL OIL,” or “ULTRA LOW SULFUR
DIESEL”. Never store fuel in the living space.
5.
Operating Temperature Range
Use heater within the range of temperatures
indicated in the right figure.
Point A: If outside temperature -20°F
than room temperature has to be 0°F or above
Point B: If outside temperature -45°F
than room temperature has to be 60°F or above
RIGHT
WRONG
GAS
KEROSENE
0
20
40
60
-20
A
B
Room Temperature (˚F)
Outside T
emperature (˚F)
-25
-30
-35
-40
-45
Operating Range
Oil Miser 23 (E) 09.1.23 11:16 AM ページ 3