![Toyotomi Oil Miser 23 Installation And Operation Instructions Manual Download Page 25](http://html1.mh-extra.com/html/toyotomi/oil-miser-23/oil-miser-23_installation-and-operation-instructions-manual_1143464025.webp)
6.
Insert the bent joint to the exhaust opening of the standard flue pipe. Cut the inlet hose for desired
length if necessary. Attach the L-shaped hose to each end of the inlet hose and attach the L-shaped hose
to the intake opening of the standard flue pipe. Secure the L-shaped hose to the intake opening with the
hose band. Plug the unused exhaust and intake opening with the caps provided with the heater. Make
sure the caps fit tightly onto the opening (See Fig. 10).
NOTE:
If the inlet hose is not smoothly inserted into the L-shaped hose, apply water or soap suds to
the inlet hose.
7.
Move the heater into position. Remove the filter and the two (2) screws holding the upper rear cover.
Connect the bent joint to the exhaust outlet opening and attach the L-shaped hose to the intake inlet
opening. Make sure all connections are tight (See Fig. 11).
25
L-Shaped Hose
Exhaust Air Cap
Intake Air Cap
Hose Band
Inlet Hose
Fig. 10
Fig. 11
Bent Joint
Oil Miser 23 (E) 09.1.23 11:16 AM ページ 25