35
10.3 Key parts checking.
10.3.1. Compressor checking (Model: DA108X1C-20FZ3).
Measure the resistance value of each winding by using the multi-meter.
10.3.2 Step Motor (Model: MP2835).
Measure the resistance value of each winding by using the multi-meter.
Position
Resistance
Value
Blue - Red
0.71Ω
(20
℃
)
Blue - Black
Red - Blue
Position
Resistance
Value
Blue - Red
200Ω±7%
(25
℃
)
Pink -
Orange
Pink - Yellow
Yellow - Red